Some Activity - Motorola PTP 600 Series User Manual

Point-to-point wireless bridges
Hide thumbs Also See for PTP 600 Series:
Table of Contents

Advertisement

If there are no faults found in the configuration and there is absolutely no wireless signal retry
the installation procedure. If this doesn't work then the ODU may be faulty.

10.2.2 Some Activity

If there is some activity but the link is unreliable or doesn't achieve the data rates required
then:
Check that the interference has not increased using the DFS measurements
If a quieter channel is available check that it is not barred
Check that the path loss is low enough for the communication rates required
Check that the ODU has not become misaligned
159

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Motowi 4 ptp 600 series