10-1-10. How to set louver lock (Louver fix)
<4-Way Discharge Cassette Type only>
1
Push
(At the right side of the button) for
UNIT
LOUVER
4 seconds or more during stop of the operation.
flashes.
2
Push
(At the left side of the button) and
UNIT
LOUVER
select the unit to be set.
• Every pushing the button, the unit No. changes.
UNIT No.
1–1
UNIT No.
The fan of the selected unit rotates and the
louver swings.
3
Push temp. set
louver No. of which air direction is to be fixed.
• The selected louver swings.
[F1]
[F2]
4
Push TIMER SET
direction of the louver of which swinging you
do not want.
Code
0001
0004
∗ If selecting above „ and ..., there may be fear of
dewing in cooling time.
5
Push
to determine the setup contents.
SET
• When the setup was determined,
To set continuously the louver lock of the other unit,
repeat operations from 2 but from 3 to set the other
louver lock in the same unit, respectively.
6
Push
TEST
to finish the setup.
0001 to 0005
(Louver fixed position code)
∗ F1 displayed at the CODE No. on the remote
controller means that the 01 louver was selected
as shown in the figure.
UNIT No.
UNIT No.
1–2
1–3
1–4
/
to display the
[F3]
[F4]
/
and select air
0002
0003
0005
mark goes on.
Louver
No.
Refrigerant pipe
Electric parts box
Drain pipe
NOTIFICATION
• Even if louver lock works, the louver temporarily
moves in the following cases.
1) During stop
2) At start of heating operation
3) During defrost operation
4) During thermostat OFF
10-1-11. How to clear louver lock
<4-Way Discharge Cassette Type
only>
In the item 4 of the louver lock setup
procedure, set the air direction to 0000.
mark goes off.
The operations from 1 to 3, 5
and 6 are same as those of the
louver lock.
10-1-12. How to set contents of save operation
1
SAVE
Push
stop of the operation.
flashes.
2
UNIT
LOUVER
Push
and select the unit to be set.
• Every pushing the button, the unit No. changes.
The fan of the selected unit rotates and the
louver swings.
UNIT No.
1–1
3
Determine the capacity restricted value when
pushing the save button of TIMER SET
• Every pushing the button, the capacity re-
stricted value can be set at 1% interval in the
range between 100% and 50%.
∗ The setting at shipment is 75%.
4
SET
Push
and then push
– 128 –
03
04
01
for 4 seconds or more during
(At the left side of the button)
UNIT No.
UNIT No.
1–2
UNIT No. 1–4
Setup value at saving
TEST
to finish the setup.
02
Code 0000
1–3
/
.