Performance Data—50Hjq - Carrier 50HJQ004-016 Product Data

Single-package rooftop standard and high efficiency heat pump units
Table of Contents

Advertisement

PERFORMANCE DATA—50HJQ
50HJQ004 (3 Tons)
Temp (F)
Temp (F)
Outdoor
Outdoor
Entering Air
Entering Air
(Edb)
(Edb)
75
75
85
85
95
95
105
105
115
115
125
125
50HJQ005 (4 Tons)
Temp (F)
Temp (F)
Outdoor
Outdoor
Entering Air
Entering Air
(Edb)
(Edb)
75
75
85
85
95
95
105
105
115
115
125
125
50HJQ006 (5 Tons)
Temp (F)
Temp (F)
1500/0.17
Outdoor
Outdoor
Entering Air
Entering Air
(Edb)
(Edb)
72
67
TC
70.2
65.3
SHC
75
75
31.6
40.6
kW
3.51
3.47
TC
68.7
63.3
SHC
85
85
31.3
40.0
kW
3.95
3.91
TC
66.7
60.6
SHC
95
95
30.7
39.1
kW
4.43
4.39
TC
63.7
55.4
SHC
105
105
29.8
37.4
kW
4.96
4.91
TC
60.2
47.9
SHC
115
115
28.8
34.8
kW
5.55
5.43
LEGEND
BF --- Bypass Factor
Edb --- Entering Dry--- Bulb
Ewb --- Entering Wet--- Bulb
kW --- Compressor Motor Power Input
SHC --- Sensible Heating Capacity (1000 Btuh) Gross
TC --- Total Capacity (1000 Btuh) Gross
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (Btuh)
t
ldb = tedb –
1.10 x cfm
t
lwb
= Wet-bulb temperature corresponding to enthalpy of air leaving indoor coil (h
COOLING CAPACITIES
900/0.12
72
67
62
TC
41.2
37.8
34.4
SHC
19.8
24.5
28.8
kW
2.11
2.08
2.05
TC
39.9
36.5
33.1
SHC
19.4
24.0
28.2
kW
2.36
2.34
2.31
TC
38.6
35.0
31.7
SHC
18.9
23.4
27.4
kW
2.65
2.62
2.58
TC
37.1
33.2
30.0
SHC
18.3
22.7
26.6
kW
2.96
2.92
2.88
TC
35.1
31.4
28.0
SHC
17.6
21.9
25.6
kW
3.29
3.25
3.20
TC
33.0
29.0
25.7
SHC
16.9
21.0
24.5
kW
3.65
3.59
3.53
1200/0.1
72
67
62
TC
51.0
48.9
43.9
SHC
24.1
33.1
40.3
kW
2.65
2.64
2.60
TC
48.9
47.1
41.9
SHC
22.9
32.2
40.2
kW
2.99
2.98
2.94
TC
47.1
45.1
39.2
SHC
22.3
31.5
39.2
kW
3.37
3.37
3.31
TC
44.9
42.9
37.5
SHC
21.3
30.7
37.5
kW
3.79
3.78
3.71
TC
42.9
40.8
35.2
SHC
20.4
30.1
35.2
kW
4.24
4.23
4.15
TC
40.9
38.2
32.9
SHC
19.8
29.1
32.9
kW
4.72
4.70
4.62
1750/0.25
62
57
72
67
59.9
56.6
71.7
66.8
49.2
54.1
33.3
43.5
3.45
3.43
3.52
3.48
57.4
54.2
70.3
65.1
48.3
51.8
33.1
43.2
3.89
3.87
3.96
3.92
52.0
50.1
68.4
62.4
46.2
47.8
32.7
42.5
4.34
4.32
4.45
4.41
45.8
45.8
65.6
58.6
43.5
43.7
31.9
41.3
4.81
4.81
4.99
4.94
41.2
41.2
62.0
50.9
39.3
39.3
30.9
38.8
5.33
5.33
5.57
5.46
lwb
)
Indoor Entering Air — Cfm/BF
1200/0.15
Indoor Entering Air — Ewb (F)
72
67
62
72
42.9
39.6
36.3
43.6
21.5
27.6
32.9
22.5
2.12
2.10
2.07
2.12
41.9
38.2
34.9
42.5
21.2
27.2
32.4
22.6
2.38
2.35
2.33
2.38
40.4
36.7
33.4
41.3
20.8
26.6
31.6
22.4
2.66
2.63
2.61
2.67
38.7
35.0
31.5
39.3
20.3
26.1
30.7
21.7
2.98
2.95
2.90
2.97
36.7
32.8
29.7
37.7
19.7
25.2
29.6
21.5
3.31
3.27
3.23
3.32
34.4
30.6
27.8
35.4
19.0
24.3
27.8
20.9
3.68
3.62
3.57
3.69
Indoor Entering Air — Cfm/BF
1600/0.12
Indoor Entering Air — Ewb (F)
72
67
62
72
52.3
50.2
46.0
53.7
26.0
37.0
44.2
27.8
2.66
2.65
2.61
2.67
50.7
48.4
44.2
52.6
25.4
36.4
43.4
27.9
3.01
3.00
2.96
3.03
49.0
46.3
42.1
50.8
24.9
35.6
42.1
27.4
3.40
3.38
3.34
3.42
46.8
44.1
40.3
48.7
24.1
34.8
40.3
26.9
3.82
3.80
3.75
3.84
44.6
41.9
38.3
46.3
23.3
34.0
38.3
26.1
4.26
4.24
4.19
4.29
42.2
39.3
36.1
43.5
22.4
33.0
36.1
25.1
4.73
4.71
4.66
4.74
Indoor Entering Air — Cfm/BF
2000/0.31
Indoor Entering Air — Ewb (F)
62
57
72
67
61.9
59.7
72.8
67.8
53.8
57.0
34.8
46.0
3.46
3.44
3.45
3.49
59.3
57.8
71.8
66.3
52.8
55.2
34.9
46.2
3.89
3.89
3.98
3.93
55.5
54.7
69.1
63.8
51.3
52.3
34.2
45.8
4.37
4.37
4.46
4.43
50.2
50.1
66.9
60.5
47.9
47.9
33.9
44.8
4.86
4.86
5.00
4.96
45.2
45.2
63.3
52.8
43.1
43.2
32.9
42.4
5.40
5.40
5.58
5.49
h
lwb = hewb –
Where:
ewb
h
= Enthalpy of air entering evaporator coil
3. The Shc is based on 80_F edb termperature of air entering evaporator coil.
Below 80_F edb, subtract (corr factor x cfm) from SHC.
Above 80_F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 --- BF) x (edb --- 80).
Shaded cells indicate Standard Ratings
85
1500/0.18
67
62
40.6
37.5
30.1
36.3
2.10
2.08
39.2
36.1
29.8
35.9
2.36
2.35
37.6
34.8
29.2
34.7
2.64
2.63
36.0
33.2
29.0
33.2
2.96
2.93
33.8
31.6
28.1
31.6
3.29
3.26
31.5
29.8
27.1
29.7
3.64
3.61
2000/0.15
67
62
51.5
48.1
40.9
48.0
2.66
2.63
49.8
46.6
40.6
46.6
3.01
2.99
47.6
44.9
39.8
44.9
3.39
3.37
45.4
43.2
39.0
43.1
3.81
3.79
43.0
41.3
37.9
41.3
4.25
4.23
40.5
39.3
36.9
39.3
4.72
4.71
2500/0.42
62
57
72
67
63.4
62.4
74.1
69.9
57.8
59.6
37.5
51.8
3.47
3.46
3.55
3.51
60.9
60.5
73.2
68.5
56.8
57.7
38.0
52.5
3.91
3.91
4.00
3.96
58.2
58.2
71.2
65.6
55.5
55.5
38.0
51.6
4.39
4.40
4.48
4.43
53.3
53.6
68.2
62.4
50.9
51.2
37.3
51.1
4.90
4.90
5.00
4.97
48.2
48.2
65.1
56.2
46.1
46.0
36.8
49.2
5.44
5.44
5.59
5.53
total capacity (Btuh)
4.5x
cfm
62
57
65.8
65.8
62.9
62.9
3.48
3.48
64.5
64.4
61.6
61.5
3.93
3.92
62.2
62.2
59.4
59.4
4.42
4.42
59.5
59.5
56.8
56.8
4.95
4.95
54.2
54.1
51.8
51.7
5.50
5.50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents