50HJQ016 (15 TONS)*
Airflow
Airflow
0.2
(Cfm)
(Cfm)
Rpm
Watts
4500
584
717
4800
609
839
5100
634
971
5400
660
1118
5700
687
1284
6000
712
1458
6300
736
1644
6600
763
1856
6900
788
2078
7200
813
2316
7500
841
2584
50HJQ016 (15 TONS)* (cont)
Airflow
Airflow
1.2
(Cfm)
(Cfm)
Rpm
Watts
4500
1070
2113
4800
1078
2269
5100
1086
2439
5400
1097
2626
5700
1110
2835
6000
1122
3053
6300
1135
3286
6600
1151
3549
6900
1167
3821
7200
1183
4113
7500
1202
4437
LEGEND
BHP --- Brake Horsepower Input to Fan
FIOP --- Factory ---Installed Option
Watts --- Input Watts
*Standard drive range is 817 to 1038 rpm. Alternate drive range is 1082
to 1303. Other rpms may require a field-supplied drive.
See General Fan Performance notes.
1. Extensive motor and electrical testing on these units
ensures that the full range of the motor can be utilized with
confidence. Using your fan motors up to the wattage
ratings shown will not result in nuisance tripping or
premature motor failure. Unit warranty will not be
affected.
For
additional
performance, refer to Indoor-Fan Motor Performance
table.
2. Values include losses for filters, unit casing, and wet coils.
See accessory/FIOP static pressure information.
FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (CONT)
External Static Pressure (in. wg)
0.4
Bhp
Rpm
Watts
Bhp
0.8
695
952
1.1
0.9
717
1085
1.2
1.1
738
1229
1.4
1.3
760
1389
1.6
1.4
783
1566
1.8
1.6
805
1752
2.0
1.8
826
1952
2.2
2.1
851
2176
2.4
2.3
873
2410
2.7
2.6
896
2662
3.0
2.9
921
2943
3.3
External Static Pressure (in. wg)
1.4
Bhp
Rpm
Watts
Bhp
2.4
1151
2458
2.8
2.5
1157
2620
2.9
2.7
1164
2795
3.1
2.9
1172
2986
3.3
3.2
1183
3200
3.6
3.4
1193
3422
3.8
3.7
1204
3660
4.1
4.0
1218
3928
4.4
4.3
1232
4207
4.7
4.6
1246
4505
5.0
5.0
1264
4837
5.4

GENERAL NOTES FOR FAN PERFORMANCE TABLES

information
on
motor
0.6
Rpm
Watts
Bhp
Rpm
798
1205
1.3
893
815
1346
1.5
907
833
1500
1.7
921
852
1669
1.9
937
873
1858
2.1
956
892
2055
2.3
973
911
2265
2.5
990
933
2502
2.8
1010
954
2747
3.1
1029
975
3011
3.4
1048
998
3304
3.7
1070
1.6
Rpm
Watts
Bhp
Rpm
1229
2819
3.2
1302
1233
2990
3.3
1306
1238
3170
3.5
1245
3366
3.8
1253
3584
4.0
1262
3810
4.3
1271
4052
4.5
1283
4325
4.8
1295
4608
5.2
NOTES:
.
1
Maximum continuous bhp is 5.90 and maximum continuous watts are
5180. Do not adjust motor rpm such that motor maximum bhp and/or
watts is exceeded at the maximum operating cfm.
.
2
Fan performance is identical for horizontal discharge applications us-
ing horizontal adapter curb (CRRFCURB013A00).
3. Use of a field-supplied motor may affect wire sizing.
Contact your Carrier representative for details.
4. Interpolation is permissible. Do not extrapolate.
5. Field- -supplied drive requires changing belt and motor
pulley to meet desired air flow. See application data or
contact your local Carrier reepresentative for details.
105
0.8
1.0
Watts
Bhp
Rpm
Watts
1483
1.7
984
1786
1630
1.8
994
1938
1791
2.0
1006
2104
1968
2.2
1019
2286
2165
2.4
1034
2490
2371
2.7
1049
2703
2591
2.9
1064
2930
2837
3.2
1082
3186
3093
3.5
1099
3451
3367
3.8
1117
3734
3672
4.1
1137
4049
1.8
2.0
Watts
Bhp
Rpm
Watts
3194
3.6
3374
3.8
Bhp
2.0
2.2
2.4
2.6
2.8
3.0
3.3
3.6
3.9
4.2
4.5
Bhp

Hide quick links: