50TFQ012 (10 TONS) — ALTERNATE MOTOR AND DRIVE*
Airflow
Airflow
0.2
(Cfm)
(Cfm)
Rpm
Bhp
3000
523
0.58
3100
536
0.63
3200
549
0.68
3300
562
0.74
3400
575
0.80
3500
588
0.86
3600
601
0.93
3700
614
1.00
3800
628
1.07
3900
641
1.15
4000
655
1.23
4100
668
1.31
4200
682
1.40
4300
696
1.49
4400
710
1.59
4500
723
1.69
4600
737
1.80
4700
751
1.91
4800
765
2.02
4900
779
2.14
5000
793
2.26
50TFQ012 (10 TONS) — ALTERNATE MOTOR AND DRIVE* (cont)
Airflow
Airflow
1.2
(Cfm)
(Cfm)
Rpm
Bhp
3000
830
1.39
3100
837
1.46
3200
843
1.53
3300
850
1.61
3400
858
1.69
3500
865
1.77
3600
873
1.86
3700
881
1.95
3800
889
2.04
3900
898
2.14
4000
907
2.24
4100
916
2.35
4200
925
2.45
4300
934
2.57
4400
944
2.69
4500
954
2.81
4600
4700
4800
4900
5000
LEGEND
Bhp --- Brake Horsepower Input to Fan
Watts --- Input Watts to Motor
* Motor drive range: 835 to 1085 rpm. All other rpms require a field-
supplied drive.
See General Fan Performance notes.
FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (CONT)
0.4
Watts
Rpm
Bhp
Watts
541
592
0.73
680
587
603
0.78
730
637
614
0.84
783
689
626
0.90
839
744
637
0.96
898
802
649
1.03
961
864
661
1.10
1026
929
673
1.17
1095
997
685
1.25
1167
1069
697
1.33
1243
1144
709
1.42
1322
1223
722
1.51
1405
1305
734
1.60
1492
1392
747
1.70
1582
1482
760
1.80
1677
1577
773
1.90
1775
1675
785
2.01
1877
1778
798
2.13
1984
1885
812
2.25
2095
1996
825
2.37
2210
2112
838
2.50
2330
1.4
Watts
Rpm
Bhp
Watts
1298
883
1.57
1466
1363
889
1.65
1534
1431
894
1.72
1606
1502
901
1.80
1680
1576
907
1.88
1758
1653
914
1.97
1838
1733
921
2.06
1922
1816
928
2.16
2010
1904
936
2.25
2100
1995
944
2.35
2195
2089
952
2.46
2293
2187
960
2.57
2395
2289
969
2.68
2500
2395
978
2.80
2610
2504
2618
External Static Pressure (in. wg)
0.6
Rpm
Bhp
Watts
657
0.88
825
666
0.94
879
676
1.00
936
686
1.07
996
696
1.14
1059
707
1.21
1125
717
1.28
1194
728
1.36
1267
739
1.44
1343
750
1.53
1423
761
1.61
1506
773
1.71
1593
784
1.80
1683
796
1.91
1777
808
2.01
1876
820
2.12
1978
832
2.24
2085
844
2.35
2195
856
2.48
2310
869
2.61
2430
881
2.74
2554
External Static Pressure (in. wg)
1.6
Rpm
Bhp
Watts
934
1.76
1638
938
1.83
1710
944
1.91
1785
949
2.00
1863
955
2.09
1944
961
2.18
2029
967
2.27
2116
974
2.37
2207
981
2.47
2302
988
2.57
2399
996
2.68
2501
1004
2.80
2607
NOTES:
1.
Shaded cells indicate field-supplied drive is required.
2.
Maximum continuous bhp is 2.90
51
0.8
Rpm
Bhp
Watts
Rpm
718
1.05
977
775
726
1.11
1035
783
735
1.17
1096
790
743
1.24
1159
798
752
1.31
1226
806
762
1.39
1296
815
771
1.47
1369
823
781
1.55
1445
832
791
1.64
1525
841
801
1.72
1608
850
812
1.82
1695
860
822
1.92
1786
870
833
2.02
1880
880
844
2.12
1979
890
855
2.23
2081
900
866
2.35
2187
910
877
2.46
2297
921
889
2.59
2412
932
900
2.71
2531
912
2.85
2654
1.8
Rpm
Bhp
Watts
Rpm
982
1.95
1815
1029
986
2.03
1891
1033
991
2.11
1969
1037
996
2.20
2051
1041
1001
2.29
2135
1046
1007
2.38
2223
1051
1012
2.48
2314
1056
1019
2.58
2409
1062
1025
2.69
2507
1032
2.80
2608
1.0
Bhp
Watts
1.22
1135
1.28
1196
1.35
1260
1.42
1328
1.50
1398
1.58
1472
1.66
1548
1.75
1629
1.84
1712
1.93
1799
2.03
1890
2.13
1984
2.23
2082
2.34
2184
2.46
2290
2.57
2400
2.70
2514
2.82
2633
2.0
Bhp
Watts
2.14
1996
2.23
2075
2.31
2157
2.40
2242
2.50
2331
2.60
2422
2.70
2516
2.80
2615

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents