Sign In
Upload
Manuals
Brands
Carrier Manuals
Heat Pump
WeatherMaker 50TCQ
Carrier WeatherMaker 50TCQ Manuals
Manuals and User Guides for Carrier WeatherMaker 50TCQ. We have
2
Carrier WeatherMaker 50TCQ manuals available for free PDF download: Product Data, Installation Instructions Manual
Carrier WeatherMaker 50TCQ Product Data (105 pages)
Packaged Heat Pump 3 to 12.5 Nominal Tons
Brand:
Carrier
| Category:
Heat Pump
| Size: 4 MB
Table of Contents
Product Data
1
Table of Contents
2
Easy to Install
2
Easy to Maintain
2
Easy to Use
2
Features and Benefits
3
Model Number Nomenclature
4
Factory Options And/Or Accessories
5
Economizer (Dry Bulb or Enthalpy)
6
CO2 Sensor
6
Smoke Detectors
6
Louvered Hail Guards
6
Disconnect Switch Bracket
7
Motormaster Head Pressure Controller
7
Alternate Motors and Drives
7
Manual OA Damper
7
Ahri Cooling Rating Tables
8
Legend
8
Ahri Capacity Rating
8
Sound Performance Table
9
Physical Data
10
Electric Heat - Electrical Data
12
Weights & Dimensions
21
Dimensions 50TCQ 04- -07
22
Service Clearance
22
Curb Dimensions 50TCQ 04- -07
23
Vertical Connections/Economizer
24
Dimensions 50TCQ 08- -09
24
Horizontal Connections/Economizer
25
Dimensions 50TCQ 12
30
Curb Dimensions 50TCQ 12
31
Dimensions 50TCQ 14
32
Option / Accessory Weights
36
Min Operating Ambient Temp (Cooling)
37
Max Operating Ambient Temp (Cooling)
37
Min and Max Airflow (Cooling Mode)
37
Application Data
37
Make an Initial Guess at Cooling Tons
38
Look up the Rooftop’s TC and SHC
38
Determine Cooling and Heating Loads
38
Selection Procedure (with 50Tcqa07 Example)
38
Cooling Capacities
39
Stage Cooling
39
Cooling Tables
39
Heating Capacities
47
Static Pressure Adders
51
Economizer
51
Electric Heaters
51
Economizer, Barometric Relief and Pe Performance
52
Barometric Relief Flow Capacity
52
Relief Flow
52
Return Air Pressure Drop
52
General Fan Performance Notes
53
Motor, 3 Ton Vertical Supply
54
Motor, 3 Ton Horizontal Supply
54
Fan Performance
54
Motor, 4 Ton Horizontal Supply
55
Motor, 4 Ton Vertical Supply
55
Motor, 5 Ton Horizontal Supply
56
Motor, 5 Ton Vertical Supply
56
50Tcqa04
57
50Tcqa05
58
50Tcqa06
59
Mca / Mocp
59
50Tcqa07
60
50Tcqd08
61
Pulley Adjustment
65
Motor Pulley Turns Open
65
Electrical Information
66
Mca/Mocp Determination Without C.o. or Unpwrd C.o.
69
Mca/Mocp Determination with Pwrd C.o.
78
Stage Cooling Typical Power Diagram
87
Typical Wiring Diagrams
87
Premierlink Option Diagram
89
Multi- -Protocol Option Diagram
90
Stage Typical Wiring Diagram
91
Sequence of Operation
93
Cooling, Unit Without Economizer
93
Cooling, Unit with Economi$Er IV
93
Heating, Unit Without Economizer
93
Heating, Unit with Economi$Er
94
Cooling, Unit with Economi$Er2, Premierlink Control and a Thermostat
94
Emergency Heat
95
Defrost
95
Automatic Changeover
95
Continuous Air Circulation
95
Rooftop Packaged Heat Pump
96
HVAC Guide Specifications
96
HVAC Equipment Insulation
96
Guide Specifications
96
Electric and Electronic Control System for HVAC
97
Sequence of Operations for HVAC Controls
98
Panel Air Filters
98
Self- - Contained Air Conditioners
98
Operating Characteristics
99
Electrical Requirements
99
Project Conditions
99
Delivery, Storage, and Handling
99
Coils
100
Refrigerant Components
100
Filter Section
101
Evaporator Fan and Motor
101
Condenser Fans and Motors
101
Special Features, Options and Accessories
101
Propeller Power Exhaust
103
Roof Curbs (Vertical)
103
Outdoor Air Enthalpy Sensor
103
Return Air Enthalpy Sensor
103
Time Guard
104
Electric Heat
104
Heating Section
104
Advertisement
Carrier WeatherMaker 50TCQ Installation Instructions Manual (68 pages)
Single Package Rooftop Heat Pump with Puronr (R-410A) Refrigerant Sizes 04-07
Brand:
Carrier
| Category:
Heat Pump
| Size: 6 MB
Table of Contents
Table of Contents
1
Safety Considerations
3
Rated Indoor Airflow (Cfm)
4
Refrigeration System Components
7
Installation
9
Jobsite Survey
9
Step 1 - Plan for Unit Location
9
Roof Mount
9
Step 2 - Plan for Sequence of Unit Installation
9
Curb- - Mounted Installation
9
Pad- - Mounted Installation
9
Frame- - Mounted Installation
9
Step 3 - Inspect Unit
9
Step 4 - Provide Unit Support
9
Slab Mount (Horizontal Units Only)
11
Alternate Unit Support (in Lieu of Curb or Slab Mount)
11
Step 5 - Field Fabricate Ductwork
11
For Units with Accessory Electric Heaters
11
Step 6 - Rig and Place Unit
11
Positioning on Curb
12
Step 7 - Convert to Horizontal and Connect
12
Ductwork
12
Step 8 - Install Outside Air Hood
13
Economizer and Two- - Position Damper Hood Package Removal and Setup - Factory Option
13
Economizer Hood and Two- - Position Hood
13
Step 9 - Units with Hinged Panels Only
14
Step 10 - Install External Condensate Trap and Line
14
Step 11 - Make Electrical Connections
15
Field Power Supply
15
Units with Factory- - Installed
18
Non- - Fused Disconnect
18
Units Without Factory- - Installed
18
All Units
18
Convenience Outlets
18
Factory- - Option Thru- - Base Connections
20
Units Without Thru- - Base Connections
20
Field Control Wiring
20
Thermostat
20
Unit Without Thru- - Base Connection Kit
21
Heat Anticipator Settings
21
Central Terminal Board
21
Commercial Defrost Control
21
Electric Heaters
23
Single Point Boxes and Supplementary Fuses
24
Single Point Boxes Without Fuses
24
Low- - Voltage Control Connections
24
Economi$Er R X (Factory- -Installed Option)
25
Product Description
25
System Components
25
Specifications
25
W7220 Economizer Module
25
Electrical
25
Inputs
25
Outputs
26
Environmental
26
S- - Bus Sensor Wiring
26
CO 2 Sensor Wiring
27
Interface Overview
27
User Interface
27
Keypad
27
Menu Structure
28
Setup and Configuration
28
Time- - out and Screensaver
28
Sequence of Operation
34
Enthalpy Settings
38
Two- -Speed Fan Operation
38
Checkout
39
Power up
39
Initial Menu Display
39
Power Loss (Outage or Brownout)
39
Status
39
Checkout Tests
39
Troubleshooting
39
Alarms
39
Clearing Alarms
39
Premierlinkt (Factory Option)
40
Supply Air Temperature (SAT) Sensor
42
Outdoor Air Temperature (OAT) Sensor
42
Economi$Er2
42
Field Connections
42
Space Sensors
45
Connect Thermostat
45
Configure the Unit for Thermostat Mode
45
Economizer Controls
46
Indoor Air Quality (CO 2 Sensor)
46
Outdoor Air Quality Sensor
46
Space Relative Humidity Sensors
47
Smoke Detector/Fire Shutdown (FSD)
47
Filter Status Switch
47
Supply Fan Status Switch
47
Remote Occupied Switch
47
Power Exhaust (Output)
48
CCN Communication Bus
48
RTU Open Control System
49
Supply Air Temperature (SAT) Sensor
51
Outdoor Air Temperature (OAT) Sensor
51
Economi$Er2
51
Field Connections
51
Space Temperature (SPT) Sensors
52
Indoor Air Quality (CO 2) Sensor
52
Outdoor Air Quality Sensor
53
Space Relative Humidity Sensor
53
Smoke Detector/Fire Shutdown (FSD)
53
Connecting Discrete Inputs
53
Communication Wiring - - Protocols
53
General
53
Local Access
54
RTU Open Controller Troubleshooting
54
Outdoor Air Enthalpy Control
56
Differential Enthalpy Control
56
Return Air Enthalpy Sensor
56
Smoke Detectors
56
Step 12 - Adjust Factory- -Installed Options
63
Step 13 - Install Accessories
63
Step 14 - Check Belt Tension
64
Unit Start- - up Checklist
67
Advertisement
Related Products
Carrier 50TCQA
Carrier 50TCQD
Carrier 50TCQA04
Carrier WeatherMaker 50TCQA07
Carrier 50TCQA05
Carrier 50TCQA06
Carrier 50TCQD14
Carrier WeatherMaker 50TCQ*04
Carrier WeatherMaker 50TCQ*05
Carrier WeatherMaker 50TCQ*06
Carrier Categories
Air Conditioner
Heat Pump
Furnace
Chiller
Thermostat
More Carrier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL