NOTE:
THE SWITCH/BRACKET ASSEMBLY MUST
BE INSTALLED SO THAT THE SENSOR SWITCH
MAKES CONTACT WITH THE BOTTOM OF THE FIRE-
BOX.
Return the front heat shield to its original position. Tighten the
rear screws. Replace the front screws previously removed.
Feed the variable speed control through the front
Figure 8.27
heat shield (opening is highlighted).
Install and the variable speed control into the
Figure 8.28
switch bracket with the control nut. Attach the control knob
to the stem of the variable speed control.
Attach the ground clip to the control panel. Attach
Figure 8.29
the ground wire extension to the ground clip. Attach the the
blower ground wire to the ground wire extension.
Page 38
Plug the blower cord into the FAN outlet on the junction box.
Refer to Figure 8.31, on the next page.
Push excess wires neatly towards the rear of the appliance.
Figure 8.30
Ensure the blower is pushed back into the bracket to allow
the replacement of the lower access door. The magnet strips
located on the blower feet are designed to hold the blower
in place.
Reattach the switch bracket with the two screws previously
removed.
Connect the variable speed control and the temperature
sensor switch to the short lead wires of the junction box by
plugging in the male and female connectors. See Figure
8.31, on the next page).
Plug appliance in. Turn the 110-120 VAC service "ON" at
the circuit breaker and turn the speed control switch to the
"ON" position.
RECOMMENDED OPERATING PROCEDURES
Ignite the fire in the appliance with the variable speed control
switch in an "ON" position. The fan will automatically turn on
when the temperature sensor switch closes at approximately
110 degrees Fahrenheit. Heated air should be delivered at
the outlet grille. The fan will continue to operate after the
appliance is turned OFF until the sensor switch opens.
Various conditions (such as appliance model, type of
appliance installation, outside air temperature vs. inside air
temperature) can contribute to the length of the time the
blower remains on after the appliance is turned OFF. The
blower can be turned off manually with the speed control
switch.