G. Vertical Termination
1. Direct Vent Pipe
STORM COLLAR
FIRESTOP
PIPE LENGTH
On vertical terminations use only Part #SLK-991DA or
like components. See pages 48-49.
Figure 5.10
Step 1.
Check the installation instructions for required 1 in. (25mm)
clearances (air space) to combustibles when passing
through ceilings, walls, roofs, enclosures, attic rafters, or
other nearby combustible surfaces. See page 16, Figure
5.15.
Check the instructions for maximum vertical rise of
the venting system, and any maximum horizontal offset
limitations. All offsets must fall within the set parameters of
the vent graph (Figure 5.2) located on page 11.
NOTE: Maximum vertical rise allowable is 40 ft. (10.7m),
Figure 5.11.
NOTE: Maximum number of 45° elbows permitted for a
vertical installation is eight, provided their installation
does not decrease maximum allowable horizontal run (as
specified by vent graph, on page 11).
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as speci-
fied.
• Do not pack air space with insulation or other
materials.
Failure to keep insulation or other materials away
from vent pipe may cause fire.
February 8, 2006
VERTICAL
TERMINATION CAP USE
PART #SLK-991DA
FLASHING
SUPPORT
BOX
WARNING
Heat & Glo · Paloma · 7031-220G
Figure 5.11
Step 2.
S
et the gas appliance in its desired location. Drop a plumb
bob down from the ceiling to the position of the appliance
flue exit, and mark the location where the vent will penetrate
the ceiling. Drill a small hole at this point. Next, drop a plumb
bob from the roof to the hole previously drilled in the ceiling,
and mark the spot where the vent will penetrate the roof.
Determine if ceiling joists, roof rafters, or other framing will
obstruct the venting system. You may wish to relocate the
appliance, or to offset, as shown in Figure 5.12 to avoid
cutting loadbearing members.
PLUMBER'S TAPE
CONNECTED TO
WALL STRAP
WALL
STRAP
Figure 5.12
40 ft. (12m)
MAXIMUM
TWO 45 DEGREE
ELBOWS