Confirm that the burner is properly lit and that the flame pattern is as desired (see fig. A, B and C below for the proper flame
patterns). If the flame pattern is other than normal, consult the Troubleshooting on page 20 for corrective action.
FIG. A
Normal: Soft blue flames with yellow
tips between I inch - 2 inches high.
Burner installation and adjustment
1. Hook should face upwards.
Flare-ups
"Flare-ups" sometimes occur when food drippings fall onto the hot heat distribution plate or burners and ignite. Some flaring is
normal and desirable as it helps impart the unique flavours associated with grilled foods. Controlling the intensity of the flare-ups
is necessary, however, in order to avoid burned or unevenly cooked foods and to prevent the possibility of accidental fire.
WARNING:
Always monitor the grill closely when cooking and turn the flame level down to LOW or OFF if flare-ups intensify.
Shutting Off Burners
1.
Always turn the valve knob(s) clockwise to the ''HIGH'' position, and then press and turn it to ''OFF''. Never force the knob
without pressing it. This could damage the valve.
2.
Promptly turn the gas supply to the "OFF" position at the propane cylinder.
3.
Close the lid of the grill.

Excess Flow Safety Valve Reset Procedure

The new regulators are equipped with a safety device that restricts the gas flow in the event of a gas leek. However,
unsafe practices of grill operation could activate the safety device without having a gas leak.
A sudden shut off of the gas flow typically occurs if you open the LP tank valve rapidly, or if one or more of the burner
control knobs is in an open position when opening the LP tank valve.
This procedure effective with all LP Tank sizes as well as Natural Gas. When performing the procedure on a Natural Gas
model, simply substitute "Natural Gas valve" for "LP Tank
To ensure the procedure is safely and successfully performed, please carefully follow these instructions:
1.
Close the LP tank valve.
2.
Turn all burner control knobs to the OFF position.
3.
Disconnect the regulator from the LP tank.
4.
Open the lid of the grill.
5.
Turn burner control knobs to HIGH.
6.
Wait at least 1 minute.
7.
Turn burner control knobs OFF.
8.
Wait for at least 5 minutes.
GSF3916
Owner's Manual
FIG. B
Out of adjustment: Noisy hard blue
flames – too much air.
1. Release the screw on venturi tube.
2. Adjust the flame by turning the collar on head
of venturi tube from back side of the grill and
do not take apart the venturi tube.
3. Tighten the screw and make certain it is
secured.
14
FIG. C
Poor combustion: Wavy, yellow
flames- too little air.
1. Overlap 14 mm between
venturi tube and nozzle
when assembling.
2. Keep the center line of
venturi tube and nozzle
on one line.