The transmitter broadcasts a signal from 39 minutes after the hour to 6 minutes after the hour (except through 11:39pm- 12:06am).
After this time, the transmitter output will go into standby and the display will indicate SB.
NOTE:
In the event of a facility wide power outage the transmitter will broadcast for 8 hours upon the restoration of
power. This will synchronize all products. In the event that the power to a transmitter is shut off and turned back
on, the transmitter will broadcast continuously for 8 hours. Power cycling the transmitter can be used to set/reset
products.
The following section summarizes how each product reacts to timed operation.

Manual Setting Battery Operated Clocks

These clocks can be identified as analog clocks with a grey set wheel located on the back side.
While using the timed transmit schedule, the battery operated clocks will update at 2, 6, and 10 am/pm.
If installing clocks after the initial 8 hour transmission, there are 2 options
1. Install clocks between 39 minutes past the hour and 6 minutes after the next hour. They will set right away.
2. Cycle power to the transmitter. It will then transmit for 8 hours and clocks will set immediately on power up.
If the clock batteries expire and are replaced when the transmitter is not broadcasting, the clock will not reset until the transmitter is
power cycled.
If 7 days pass without the clock receiving a signal from the transmitter, it will begin double stepping (taking two steps every two
seconds) to alert the user of a signal reception problem

Automatic Setting Battery Operated Clocks

These clocks can be identified as analog clocks that do not have grey set wheel
While using the timed transmit schedule, the battery operated clocks will update at 2, 6, and 10 am/pm.
If installing clocks after the initial 8 hour transmission, there are 2 options
1. Install clocks between 39 minutes past the hour and 6 minutes after the next hour. They will set right away.
2. Cycle power to the transmitter. It will then transmit for 8 hours and clocks will set immediately on power up.
If the clock batteries expire and are replaced when the transmitter is not broadcasting, it will not reset until the transmitter is power
cycled.
If 4 days pass without the clock receiving a signal from the transmitter, it will begin five stepping (taking five steps every five seconds)
to alert the user of a signal reception problem.

AC Powered Analog Clocks

While using the timed transmit schedule, the clocks will update at 2, 6, and 10 am/pm. If a signal is not received at a specific update
time, the clock will continue to search for a signal until it receives one.
If installing clocks after the initial 8 hour transmission, there are 3 options
1. Install clocks between 39 minutes past the hour and 6 minutes after the next hour. They will set right away.
2. Install the clocks any time of the day. They will not set until 39 minutes after the hour.
3. Cycle power to the transmitter. It will then transmit for 8 hours and clocks will set immediately on power up.
If 4 days pass without the clock receiving a signal from the transmitter, it will begin five stepping (taking five steps every five seconds)
to alert the user of a signal reception problem.