Error messages

When multiple amplifiers are connected by F.C.B.S., the error messages described in the
table below may be displayed on the display. In such a case, ID number setting or remote
cable connection may be in failure. Check the ID number or remote cable connection, referring
to the table below. For details on ID number setting, see "Setting ID number for F.C.B.S"
(vpage 18).
Indication
1
ERROR 02
Multiple amplifiers take ID No. 2.
2
ERROR 03
Multiple amplifiers take ID No. 3.
3
ERROR 04
Multiple amplifiers take ID No. 4.
! Assign different ID numbers to the amplifiers.
4
ERROR 11
The amplifiers with ID Nos. 2-4 cannot communicate with the
amplifier with ID No. 1.
! If the amplifier with ID No. 1 is not on, turn it ON.
! Check that the remote cable is properly connected.
5
ERROR 12
The amplifier with ID No. 1 cannot communicate with the amplifiers
with ID Nos. 2-4.
! If multiple amplifiers take ID No. 1, set ID numbers properly.
! If the amplifier with ID No. 1 is connected to the amplifier with ID No. 0, set ID numbers
properly.
! Check that the remote cable is properly connected.
Troubleshooting
Meaning
ENGLISH