Hardwire version
(input & output hardwired)
Figure 4, Bottom Side Features
15, AC output connection -
Hardwire versions - AC knockout (output) for hardwiring.
GFCI versions - provided with a Ground Fault Circuit-
Interrupter outlet (with test and reset capability).
16, AC input connection -
Hardwire versions - AC knockout (input) for hardwiring.
GFCI versions - provided with a flexible AC input cord for direct
connection to an AC outlet.
17, DC Ground terminal - this connection is used to tie the exposed
chassis of the inverter to the DC grounding system. This terminal
accepts CU/AL conductors from #14 AWG to #6 AWG.
Battery Temperature Sensor (Battery Charger Models Only)
Figure 5, BTS
©2006 Magnum Energy Inc.
http://www.wholesalesolar.com/inverters.html
1.0 Introduction
GFCI version
(input cord & GFCI outlet)
16
17
A plug-in external Battery
Temperature Sensor (BTS) is
provided for units with the battery
charger feature. When installed, the
BTS automatically adjusts the
battery chargers BULK, ABSORB and
FLOAT voltage setpoints based on
temperature. If the temperature
sensor is NOT installed and if the
batteries are subjected to large
temperature changes, the battery
life may be shortened.
15
5