Appendix A - Remote Control and Monitoring

Appendix A - Remote Control and Monitoring
There are several remotes that let you monitor and switch the inverter
on/off from a convenient location. Using the supplied cable with RJ11
connectors, they connect easily to the REMOTE port located on the
front side of the MM Series (see figure 3, item 10).
Depending on your inverter model, you can select one of the following
remotes:
MM-R - Provides three LED indicators for inverter status and includes a
remote ON/OFF switch; comes with 25' cable. This remote is for MM
Series inverters without the battery charger feature; such as the
MM612 (requires serial number L1-201 or higher) or MM612G models.
MM-RC - Provides six LED indicators for inverter and charger status,
includes a remote ON/OFF switch; comes with 25' cable. This remote is
for MM Series inverters with the battery charger feature; such as the
MM612AE, MM1212 or MM1212AE models.
ME-RC50 - Full feature remote with backlit LCD display and LED
indicators for inverter and charger status. Provides full menu access for
easy selection and adjustment; comes with 50' cable. The ME-RC50 is
used for many inverter models and has additional features that are not
functional with the MM Series inverter. Can be used with all MM Series
inverter models (MM612 requires serial number L1-201 or higher).

Using the MM Remotes

The
MM remotes
performs the same function as the ON/OFF switch on
the
front of the MM Series inverter and
operational modes of the inverter. The appropriate remote to use,
depends on whether your inverter includes the battery charger feature.
For MM Series inverters that do not have the battery charger, the MM-R
is the recommended remote; for MM Series inverters that do have the
battery charger, the MM-RC is the recommended remote.
MM-R
INVERT
AC IN
ON/OFF
FAULT
3 LED'S for
inverter operation
30
http://www.wholesalesolar.com/inverters.html
provides status of the different
INVERT
FAULT

Figure 13, MM Remotes

http://www.wholesalesolar.com/inverters.html
MM-RC
BULK
ABSORB
AC IN
ON/OFF
FLOAT
3 additional LED'S
for charger operation
©2006 Magnum Energy Inc.