Lamp Replacement - Sanyo PLC-XE30 Owner's Manual

Table of Contents

Advertisement

Maintenance and Cleaning

Lamp Replacement

When the life of the projection lamp of this projector draws
to an end, the LAMP REPLACE indicator emits a yellow
light. If this indicator lights yellow, replace the lamp with a
new one promptly.
WARNING:
TURN OFF THE UV LAMP BEFORE
OPENING THE LAMP COVER
CAUTION
Allow a projector to cool, for at least 45 minutes
before you open the Lamp cover. The inside of
the projector can become very hot.
Follow these steps to replace the lamp.
1
Turn off the projector and disconnect the AC power
cord. Allow the projector to cool for at least 45
minutes.
2
Remove the screw with a screwdriver, and remove
the lamp cover.
3
Remove 2 screws of the lamp with a screwdriver and
pull out the lamp by grasping the handle.
4
Replace the lamp with a new one and tighten the 2
screws back into position. Make sure that the lamp is
set properly. Replace the lamp cover and tighten the
screw.
5
Connect the AC power cord to the projector and turn
on the projector.
6
Reset the lamp replacement counter.
See "Lamp Replacement Counter" on the next page .
ORDER REPLACEMENT LAMP
Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following
information to the dealer.
Model No. of your projector
Replacement Lamp Type No.
56
This indicator is yellow when
the life of the projection lamp
draws to an end.
CAUTION
For continued safety, replace with a lamp of the
same type. Do not drop a lamp or touch a glass
bulb! The glass can shatter and may cause injury.
Lamp Cover
Lamp
Screw
: PLC-XE30
: POA-LMP93
(Service Parts No. 610 323 0719)
http://www.pureglare.com.au
Top Control
POWER WARNING LAMP REPLACE
Screw
Screw
Handle
Do not open the little compartment.