Delta3 - Neat Version - Electrolux washing machine Service Manual

Diagnostics guide to ewm2000 electronic control washing machines & washer dryers
Hide thumbs Also See for washing machine:
Table of Contents

Advertisement

To access the system:
→ press the SKIP/RESET button to cancel the programme
previously selected and switch off the appliance.
→ press the START/PAUSE (7) button together with the
SKIP/RESET (8) button and then, holding down both buttons,
press the ON/OFF button to switch on the appliance.
→ hold both buttons (START/PAUSE and SKIP/RESET) down until
the buzzer sounds and the LEDs begin to flash (about 4
seconds)
After accessing the diagnostics routine, the display board is
checked for correct operation. All the LEDs (and, if featured, the
display) light in sequence.
→ Press the FABRICS button (1) to pass to the subsequent phase
of the test (LED L1 lights). Press the FABRICS button again to
increment the number of the phase controlled. After the last
phase, the display returns to its normal condition. The LED
corresponding to the phase being tested lights (L1 .L10).
→ Press the TEMPERATURE button (2) to decrement the number
of the phase controlled. After the last phase, the display returns
to its normal condition(L10
To read the last alarm condition, after accessing the diagnostics
system:
→ press the FABRICS or TEMPERATURE buttons until LED L9
lights.
To cancel the last memorized alarm condition:
→ press button no. 2 (TEMPERATURES) and no. 4 at the same
time during one of the 8 phases of the diagnostic cycle and not
in the alarm or configuration reading positions.
→ the alarm is cancelled also when a new configuration is given to
the main PCB.
To access the machine configuration procedure, first enter the
diagnostics system, and then:
→ press the FABRICS (1) or TEMPERATURE (2) buttons until LED
L10 lights; the code relative to the first of the 16 digits of the
configuration code (position 0) is displayed.
→ when the SKIP/RESET button (8) is pressed, all the digits which
make up the configuration code are displayed in sequence.
→ press the START/PAUSE button (7) to modify the configuration
code (digit by digit).
→ when all 16 digits have been entered, check that the code is
correct, then memorize the code by pressing the
START/PAUSE (7) and SKIP/RESET (8) buttons at the same
time; these buttons should be held down for at least 4 seconds
(i.e. until the buzzer sounds).
→ To exit the diagnostic cycle, switch the appliance off, then on,
then off again.
SSD-P APdV, EB, HD 01/05