E92
Inconsistency between configuration values on starting the appliance
Checks to perform:
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
E93
Inconsistency between configuration values on starting the appliance
Checks to perform:
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
E94
Inconsistency between configuration values on starting the appliance
Checks to perform:
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
E97: Inconsistency between control selector version and configuration
E97
Discrepancy between programme configuration data and selector recognition data
Checks to perform:
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
E98: Communication error between main PCB and Inverter board
E98
Incompatibility between the main circuit board and the Inverter board
Checks to perform:
Replace the main circuit board / Inverter board and repeat the diagnostic cycle to check for any further
2013 TS/DT-mdm FCPD-dp
Guide to diagnostics of EWX11831 electronic controls
E92: protocol incongruence
Incorrect configuration possible.
E93: Appliance configuration error
Incorrect configuration possible.
E94: Incorrect configuration of washing cycle
Incorrect configuration possible.
Incorrect configuration possible.
Incorrect configuration possible.
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
data
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
alarms.
If there are burns on the circuit board,
!
60/71
E92
E93
E94
E97
E98
see page 69
599 77 00-82 Rev. 01