Fireplace Placement Requirements; Minimum Framing Dimensions; Clearances - FireplaceXtrordinair 2000 36 DV XL Owner's Manual

Built-in direct vent fireplace
Table of Contents

Advertisement

Installation

Fireplace Placement Requirements

Minimum Framing Dimensions

The 1/2" stand-offs on the back and sides and 6-1/4" stand-offs on the top of the fireplace are
designed to separate the fireplace from the framing members. These stand-offs may contact the
framing members but no material may be placed between the stand-offs.
46-1/2"
43-1/4"
Fireplace must be installed on a level surface capable of supporting the fireplace and vent
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)
Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.

Clearances

When installed, walls in front of the fireplace must be a minimum 4-1/2" to the side of the faceplate.
Fireplace must be placed so that no combustibles are within, or can swing within 36" of the front of the
fireplace (e.g. drapes, doors)
Fireplace must be placed so the vents below and above the glass do not become blocked
Travis Industries
(for qualified installers only)
19-5/8"
9 3 5 0 8 1 1 8
NOTE: if venting directly to the rear,
make sure there is a min. 8-5/8" space
centered behind the fireplace for the
wall thimble. If a 90° elbow is used
directly off of the fireplace, the thimble
will be centered 51-1/4" above the
base of the fireplace.
If using a remote control or
thermostat, route the wire to a
location near the gas line (include
an extra 3' length for hookup).
Gas line (3/8" M.P.T. or 1/2" F.P.T.)
should be routed 6-5/8" behind the
framing opening and 1-7/8" above
the base of the fireplace (see "Gas
Line Connection" for details).
Route the electrical line to a position
at the right rear of the fireplace.
NOTE: If using the power heat vent,
allow for the duct passage when
framing the enclosure.
7
2 7 0 9 0 0