Installation

Electrical Connection

!
Make sure the household breaker is shut off prior to working on any electrical lines.
!
The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)
The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)
1
Follow the directions below to connect power to the fireplace.
Remove the cover from the
a
fireplace junction box.
WARNING: Make sure power is
off from the power lead before
conducting any wiring.
Travis Industries
(for qualified installers only)
Attach the common (white), ground (exposed or green) wires, and hot
c
(black) wires from the power source to the electrical connector (included
with the fireplace). Then attach the connector to the fireplace.
NOTE: If using the power heat duct, you may wish
to route the wiring for it at this point. See the
instructions under "Optional Equipment".
9 3 5 0 8 1 1 8
Insert the sheathed cable from the power source through
b
this cable clamp. Once the wires are attached, tighten
the clamp to secure the cable.
Electrical
Connector
2 5
Standard
Screwdriver
d
Replace
the cover
removed
in step "a".
2 7 0 9 0 0