Mode-out • Remaining capacity

Mode-out 1 to 4

The recorder status is output from the MODE OUT terminals
on the rear panel (by short-circuiting the contact). There
are 4 MODE OUT terminals and you can allocate different
output signals to them individually.
1 Set the trigger for each MODE OUT terminal (1 to
Step
4).
[REC]: A trigger signal is output during recording.
[Play]: A trigger signal is output during playback.
[Remain 1]: A trigger signal is output when the
remaining capacity of HDD reaches the level
designated by [Remain 1] at the bottom of the
screen.
[Remain 2]: A trigger signal is output when the
remaining capacity of HDD reaches the level
designated by [Remain 2] at the bottom of the
screen.
[Power on]: A trigger signal is output while the
power of the recorder is on.
[Alarm]: A trigger signal is output during alarm
recording and emergency recording.
[LAN]: Signal output is controlled via the LAN-
connected PC.
[LAN(2s)]: Mode-out is kept active for about 2
seconds by the control from the LAN-connected PC.
[LAN(10s)]: Mode-out is kept active for about 10
seconds by the control from the LAN-connected PC.
[Off]: No signal is output.
2 Set the mode-out output status in [Polarity].
Step
[Open]: The contact is opened when the mode-out
is active.
[Close]: The contact is closed when the mode-out is
active.
Notice
When you enable the warning about remaining
capacity by the MODE OUT terminal, the mode-out
output status is maintained even though you turn off
the power by pressing the POWER button.

Remain 1 and 2

Warning is issued to notify that the remaining capacity runs
short during recording. You can designate the device and
threshold level of the remaining capacity.
Warning is issued in the following ways when the remaining
capacity decreases to the threshold level.
When the display of the operation mode is enabled,
"REM" is displayed to the left of the remaining capacity
displayed on the screen. (
To set the buzzer or call-out, see
1 Select a device.
Step
[Normal]: Warning is displayed when the capacity of
the normal recording area decreases to the threshold
level.
[Alarm]: Warning is displayed when the capacity of
the alarm recording area decreases to the threshold
level.
[EMR]: Warning is displayed when the capacity of
the emergency recording area decreases to the
threshold level.
[Archive]: Warning is displayed when the capacity
of the archive device decreases to the threshold
level.
[Off]: Warning is not issued even when the HDD
capacity decreases to the threshold value.
2 Set the threshold level of the remaining capacity.
Step
Set the threshold level for issuing warning.
Notice
Only areas created by the partition setting (
41) are displayed.
page 22)