Sec tio n 4 ·
Ope rati on
4.5 Level 2 menu - Confi guration mode
ACTION
To access confi guration mode (level 2), press both keys
simultaneously for approx. 1 second. Pressing key "1"
now switches to the next menu item and changes can be
made in the respective menu item by pressing key "2".
The setting value increases each time key "2" is pressed.
If the maximum value has been reached, the value returns
to the minimum setting choice. The various settings are
shown in fi gure 4.5.
Time set (hour)
Time set (minute)
Date set (year)
Date set (month)
Date set (day)
Display of software version
Clear the power meter
Select and set RS485
interface address
Quick start
Figure 4.5: Confi guration mode menu
Setting the time and date
The setting values are continuous, i.e. after you reach the
maximum value, the display returns to the minimum value the
next time key "1" is pressed. When setting the year in the
date display, the year setting value goes up to 2050. It then
returns to 2005.
Clearing the grid feed meter
When the grid feed meter is cleared, the values for "Daily
peak capacity", "Yield today", "Annual yield", "Total yield",
"Operating hours today", "Annual operating hours" and "Total
operating hours" are cleared. The required code is "2" and is
entered using key "2".
Operating Instructions Powador 1501xi/2501xi*/3501xi/4501xi/5001xi**
NOTE
The grid feed meter can only be cleared. You cannot set
the meter to a specifi c value.
Choice of interface and address setting
With the menu item "Select interface", you can use key "2" to
switch between the RS232 and RS485 interfaces.
If the RS485 interface is activated, you can reach the address
setting by pressing key "1". You can set the address from 1 to
32 by continuously pressing key "2". The address then returns
to 1.
The RS485 interface is used to communicate with the
Powador-proLOG. If several inverters are connected to a
Powador-proLOG, each address may only be used once. It is,
therefore, possible to monitor 32 Powador inverters with one
Powador-proLOG.

4.6 Night start-up key

Figure 4.6: Underside of the Powador
Legend
1
Night start-up key
For activating the display after nightfall
2
RS232 interface
The unit switches off in the evening as nightfall approaches.
The display is no longer shown. In order to retrieve the values
for the current day after the display has switched off, the unit
can also be activated during the night by pressing the night
start-up key (see fi gure 4.6).
ACTION
To do this, press the night start-up key "1" on the underside
of the unit for approx. 5 seconds until a display appears.