Check

Manually check the HDD for failure or errors.
1.
Select START CHECK and press ENT set to ON or
OFF.
2.
The DVR will check the system HDD for errors.
Note
If there are any HDD errors, the system will
display a pop-up detailing the problem.

SMART Check

SMART – (Self Monitoring Analysis & Reporting Technology)
Enable SMART to detect signs of HDD failure.
1.
Select SMART ENABLE and press ENT set to ON or
OFF.
2.
Set a CHECK INTERVAL between 1 and 24 hours.
3.
Define a temperature threshold and select Celsius or
Fahrenheit.
Note
The recommended upper optimum operating
temperature for the HDD is between 40C and 50C
(or 104F to 122F).
4.
Select a warning to be activated when the HDD
reaches the defined threshold.
5.
Select SAVE and press ENT to save settings.
Tip
Select HDD INFORMATION and press the ENT button to view the current HDD, DVD, and USB drive
information.