BHT-604BW
Error No.
The Transfer Utility "Communication port"
option specification is illegal.
The transmission speed at the BHT and PC
does not match.
The protocol specified at the BHT and PC
does not match.
The PC communication port setting is illegal.
Hardware malfunction
The protocol specified at the BHT and PC
53
does not match.
The protocol specified at the BHT and PC
does not match.
An attempt was made to download a file with
55
field width differing from that of the data file
already existing in the BHT.
Illegal characters have been used in the file
55
name.
71
The
USB-COM
75
incorrectly installed.
Illegal field information specification option
91
when transmitting data file.
An attempt was made to download a file with
field width differing from that of the data file
already existing in the BHT.
91
The size of the file being downloaded
exceeds the size of the available space in
the BHT user area.
Illegal characters have been used in the file
name.
BHT-Ir/BHT protocol was used for transfer
Other
for a BHT-BASIC 4.0 format program file
(*.PD4).
184
Cause Details
port
drive
has
been
Remedy
Specify the communication port to which the BHT is
connected for the "Communication port" option.
Ensure that the transmission speed at the BHT and
PC matches.
Please be aware that the default transmission
speed differs depending on the BHT used.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
Enable "Use FIFO buffer. (16550 interchangeable
UART required.) (U)" setting for the communication
port used.
Please contact your dealer.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
It is not possible to download a file with the same
name but different field width from the file already
existing in the BHT.
Either delete the existing data file in the BHT, or
specify the same field format as the existing data
file.
Change the file name.
Refer to QBdirect (page 185, Note 1) for details of
characters that can be used in file names.
Reinstall the USB-COM port driver.
Set a correct value for the field information option.
It is not possible to download a file with the same
name but different field width from the file already
existing in the BHT.
Either delete the existing data file in the BHT, or
specify the same field format as the existing data
file.
Reduce the file size or delete any unwanted files in
the BHT.
Change the file name.
Refer to QBdirect (page 185, Note 1) for details of
characters that can be used in file names.
Use Ymodem protocol or convert program files
to "*.PD3".