General Specifications - Advantech ACP-4001 User Manual

19" rackmount 4u height industrial chassis with display
Table of Contents

Advertisement

1.2 General Specifications

General
• Construction: Heavy duty steel chassis
• Drive bay: Shock-proof and front accessible 5.25" by three drivers
• Cooling system: Dual easy-to-replace 84 ~ 114 CFM cooling fans with
front-accessible air filters
• Controls: Power switch (on-off or momentary) and reset switch
behind lockable doors
• LED Indicator: Power LED for system power status
• Connectors: Front accessible USB and PS/2 keyboard, rear panel 9-pin
connector (9-pin connectors are not included in the M/B version)
• Paint Color: Pantone 4C 2X Black, textured
• Operating temperature: 0° ~ +40°C (32°F ~ 104°F)
• Storage temperature: -40° to +60°C(-40° to +140°F)
• Relative Humidity: 10 ~ 95%@40°C, non-condensing
• Vibration: (Operating) 5Hz ~ 500Hz, 1G rams
• Shock (operating): 30 G with 11m Sec duration, 1/2 sine wave
• Acoustic Noise: Less than 52 dB sound pressure at +5° to +28°C (+41°
to +82°F)
• Altitude: 0 to 3048m (0 to 10,000 ft)
• Slide rails: General Device C-300 series supported
• Dimensions: 482(W) x 173(H) x 480(D) mm (19"x 6.8" x 18.9")
• Weight: 16-18kg (35.2 - 39.6lb)
• Safety: CE compliant, UL/cUL approved, FCC/CCC for integrated
system
HDD LED for HDD activity
(Non-operating) 2G
3
Chapter 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACP-4001 and is the answer not in the manual?

Table of Contents