ProxyServer User Guide Introduction Welcome to Multi-Tech’s new ProxyServer™, model number MTPSR3-200, a single, secure gateway that provides multiple LAN users with high performance Internet access. The ProxyServer functions as a TCP/IP proxy server that resides on the outer edge of your firewall and provides up to 168K of bandwidth to LAN users.
Chapter 7 provides instructions on getting service for your ProxyServer at the factory, a statement of the limited warranty, information about our user bulletin board service, and space for recording information about your ProxyServer prior to calling Multi-Tech’s Technical Support. MTPSR3-200...
First, choose a domain name for your company. A domain name is the unique Internet name, usually the name of your business, that identifies your company. For example, Multi-Tech’s domain name is multitech.com (where .com indicates this is a commercial organization; .edu denotes educational organizations, .gov denotes government organizations). Next, determine how many IP addresses you’ll need.
Page 9
Ping uses ICMP Echo messages. • Whois/NICNAME: Utilities that search databases for information about Internet domain and domain contact information, per RFC 954 ( ftp://ds.internic.net/rfc/rfc954.txt). • Traceroute: a tool that displays the route that packets will take when traveling to a remote host. MTPSR3-200...
You first choose a domain name for your company. A domain name is the unique Internet name, usually the name of your business, that identifies your company. For example, Multi-Tech’s domain name is multitech.com (where .com indicates this is a commercial organization; .edu denotes educational organizations, .gov denotes government organizations). Next, you determine how many IP addresses you’ll need.
Terminal Ready indicator blinks when the link is ready to transfer data. FAIL Fail indicator lights when a self test fails to complete as expected. POWER The power indicator lights when the On/Off Switch is in the ON position. MTPSR3-200...
The Power connector is used to connect the external power supply to the ProxyServer. The Power connector is a 6-pin circular DIN connector. A separate power cord is connected to the power supply and the live AC grounded outlet. Applications Applications to be supported later. MTPSR3-200...
PC with Windows 3.1x, and one serial comm port to connect to the Command Port of the ProxyServer Though this modem is capable of 56K bps download performance, line impairments, public telephone infrastructure and other external technological factors currently prevent maximum 56K bps connections. MTPSR3-200...
Multi-Tech’s Technical Support for advice (refer to Chapter 7). If no damage is observed, place the ProxyServer in its final location and perform the Installation Procedure in Table 2-1. Save the shipping box in case reshipment is necessary. MultiExpress Quick Start Guide Figure 2-1. Unpacking MTPSR3-200...
ProxyServer. Connect the other end of the cable to the line jack. Connect the second RJ11 phone cable to the LINK 2 connector on the ProxyServer and the other end to the second line jack. Connect the third RJ11 phone cable to the LINK 3 connector and to the third line jack. MTPSR3-200...
Turn the ProxyServer upside down and replace the two cabinet mounting screws that were removed in step 2. Turn the ProxyServer right side up and return to Table 2-1 to connect the cables. MTPSR3-200...
Dynamic Address check box to disable the feature, then click on the IP Address field and enter your IP WAN 1 address. Also, enter the Net Mask for WAN 1. Highlight WAN 2 and repeat the above process. Highlight WAN 3 and repeat the above process. MTPSR3-200...
Page 21
19. Click on User Name for WAN 1 and enter your user name that you negotated with your ISP for WAN 1. The User Name can be up to 40 alphanumeric characters. The User Name is not case sensitive. MTPSR3-200...
Page 22
26. Win3.1 users - you are returned to your Program Manager where the Proxy Server Program Group and Program Item (Windows icons) have been created. Win95 users - you are returned to your ProxyServer folder which will be visible on your desktop. MTPSR3-200...
You may also run Proxy Server Configuration from either the Program Manager or the File Manager by clicking on the Run command in the File Menu, then typing: C:\ proxy\ roucon.exe in the Command Line field. Local port setup can also be run from the Command Line by typing: C:\ proxy\ psetup.exe. MTPSR3-200...
ProxyServer setup also has a console terminal for displaying various debugging messages output from the target. You can control the display of these messages using this application. Normally you should turn off the display of all messages for better performance of the router. MTPSR3-200...
255.0.0.0, 255.255.0.0 and 255.255.255.0 respectively unless other subnets have been set up. The net mask specifies the network or subnet portion of an IP address. The net mask is a 32-bit value presented in a dotted decimal notation. MTPSR3-200...
Compression) option. SLIP requires that an authentication script be written when you are in the WAN Port Setup dialog box. When you have SLIP configured for your network, click on the OK button to return to the Proxy Setup dialog box. MTPSR3-200...
WAN port. You can click on the Script Enable option to activate a script for the selected WAN port. You can also Restart a Script On Communication Failure by clicking on this option. Refer to Appendix B for details on the Router Scripting Language. MTPSR3-200...
In the Options Types and Values dialog, you can customize the configuration of the client platform. The Option Type and Name are displayed in the left dialog and the values for that option are displayed in the right dialog. You can Add and Remove values using the respective buttons. MTPSR3-200...
The WEB Server interface allows you to configure the Proxy Server remotely via your WEB browser on your local network. By entering the IP address of the Proxy Server in the Location (Address) field of your browser, your are brought to the Multi-Tech Proxy Server Configuration site. MTPSR3-200...
Page 31
Stacks, Device Drivers, Other Setup, and statistics for the WAN ports. Each category contains links which allow configuration of various features. Click on the item you wish to configure and you are brought to a configuration screen for that feature. MTPSR3-200...
Diagnostic dialog box is displayed by clicking on the Diagnostic button in the Router Setup dialog box. Diagnostic tests are performed if the Communication type of the Local Port configuration is set to COM Port. If the Local Port configuration is set for IP, no diagnostic test are performed by the ProxyServer. MTPSR3-200...
At the main site, connect your local PC to a modem that is connected to a dial-up line. Install the ProxyServer software on the local PC and at the Windows Program Manager screen, double click on the Configuration Port Setup Icon. The ProxyServer Setup dialog box is displayed. MTPSR3-200...
Page 35
The Reading Setup Dialog Box is displayed. The ProxyServer Setup dialog box is then displayed. This is the dialog box of the remote ProxyServer. Refer to the Menus Chapter (Chapter 4) for the definition of each dialog box and field within a dialog box. MTPSR3-200...
Page 36
Port Setup dialog box. 14 At the remote site, reconnect the ProxyServer to the serial port of the PC and from the Program Manager screen click on the Proxy Server Configuration icon to verify that the ProxyServer is running. MTPSR3-200...
Verify that the Communication Type field is set to IP. In the Router IP Address field, enter the IP Address of the remote ProxyServer. Click on OK when you are satisfied with your selections. The Windows Program Manager menu is displayed. MTPSR3-200...
Page 38
Click on the Exit button when the downloading is complete. Click on the Proxy Server Configuration icon in the Program Manager screen to verify that the ProxyServer is running. MTPSR3-200...
The proxy server configuration options allow you to select the protocol stack, high or low level device drivers, applications, proxy server, or system information. The WAN device configuration allows you to gain access to the WAN ports. MTPSR3-200...
Dumb TTY - The Dumb TTY allows a remote user to connect to the ProxyServer’s command port for configuration and management of the ProxyServer. MTPSR3-200...
Defective products must be returned by Customer to MTS’s factory transportation prepaid. MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PURCHASE PRICE FOR DEFECTIVE PRODUCTS. MTPSR3-200...
Also, note the status of your ProxyServer including LED indicators, screen messages, diagnostic test results, DIP-Switch settings, problems with a specific application, etc. Use the space below to note the ProxyServer status: ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ ______________________________________________________________________________________________________________ ______________________________________________________________________________________________________ ______________________________________________________________________________________________________________ ______________________________________________________________________________________________________ MTPSR3-200...
Send your ProxyServer to this address: MULTI-TECH SYSTEMS, INC. 2205 WOODALE DRIVE MOUNDS VIEW, MINNESOTA 55112 ATTN: SERVICE OR REPAIRS You should also check with the supplier of your ProxyServer on the availability of local service and/or loaner units in your area. MTPSR3-200...
4. Mark one or more files for download by entering M, the list numbers of the files, and a RETURN. 5. Enter D. You will see a list of the files you have marked. Enter E if you would like to edit the list; otherwise enter D again to start the download process. MTPSR3-200...
If you prefer to receive technical support via the Internet, you can contact Tech Support via e-mail by clicking on the following link: Technical Support E-mail Multi-Tech’s presence includes a Web site at: http://www.multitech.com and an ftp site at: ftp://ftp.multitech.com The ftp server mirrors the Multi-Tech BBS. MTPSR3-200...
From the catalog of available documents, you can order newsletters, white papers, press releases, etc. from the sales and marketing index (pages 1-4), or order basic modem operation and troubleshooting guides from the technical support and engineering index. Just enter the applicable FB Doc. # from the left column of the catalog. MTPSR3-200...
RD- Data Receive Negative Remote Configuration Cable PIN NO. PIN NO. FRAME GROUND TRANSMIT DATA (TX) RECEIVE DATA (RX) Device REQUEST TO SEND (RTS) (Communication Device CLEAR TO SEND (CTS) COMMAND PORT i.e. Modem) Connector SIGNAL GROUND Male Male MTPSR3-200...
An example of forward defined procedures is given below: proc a(integer x,y) : integer,forward: proc b(integer u,v) : integer,forward: proc a; integer t; /*Some more code here. */ t=b(x,y); /*Some more code here. */ return(t); endproc proc b; return(a(u,v); endproc MTPSR3-200...
Page 54
Binary Operators :*/ + _< > <= >= == ! = && II All the operators are left associative. Expressions are evaluated completely; so care must be taken while writing expressions. For example, expressions like (a !=0 && b / a) would create run time error. MTPSR3-200...
Tech Systems, Inc., at the address shown below for details of how to have repairs made. If the equipment is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved. MTPSR3-200...
Page 56
9. If so required, this equipment is hearing-aid compatible. Manufacturer: Multi-Tech Systems, Inc. Trade name: ProxyServer 200-Series Model Numbers: MTPSR3-200 FCC Registration Number: AU7USA-24994-M5-DE Ringer Equivalence: 0.6B Modular Jack (USOC): RJ11 Service Center in U.S.A.: Multi-Tech Systems Inc.
No repairs are to be made by you. Repairs are to be made only by Multi-Tech Systems or its licensees. Unauthorized repairs void registration and warranty. Manufacturer: Multi-Tech Systems, Inc. Trade Name: ProxyServer 200-Series Model Number: MTPSR3-200 FCC Registration Number: AU7USA-24994-M5-DE Ringer Equivalence Number: 0.6B Modular Jack (USOC): RJ11 Service Center in USA: Multi-Tech Systems, Inc.
Page 58
ProxyServer User Guide Modem CE Mark EMC and Safety Compliance The CE mark is affixed to the enclosed MultiTech product to confirm compliance with the following European Community Directives: Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member States relating to electromagnetic compatibility;...
Select V.21 when the modem is at 300 bps. Select Bell 103J when the modem is at 300 bps. Command: Carrier Control n = 1 Values: Default: Description: C0 Transmit carrier always off. (Not supported.) Normal transmit carrier switching (included for backward compatibility with some software). MTPSR3-200...
Page 60
Display firmware version for data pump (e.g., “94”). Display country code (e.g., “NA Ver. 1”). Display Diagnostic Information for the last Modem Connection (i.e., DSP and Firmware version, Link Type, Line Speed, Serial Speed, Type of Error Correction/Data Compression, Number of past Retrains,etc.) MTPSR3-200...
Page 61
Read value of register S r and display value in 3-digit decimal form. Description: Command: Result Code Format Values: n = 0 or 1 Default: Description: V0 Displays result codes as digits (terse response). Displays result codes as words (verbose response). MTPSR3-200...
Page 62
Command: V.22bis Guard Tone Control Values: n = 0, 1, or 2 Default: Description: &G0 Disable guard tone. &G1 Enable 550 Hz guard tone. &G2 Enable 1800 Hz guard tone. The &G command is not used in North America. MTPSR3-200...
Page 63
Command: &Z n = x Store Telephone Number Values: n = 0, 1, 2, or 3 x = Dialing string Default: None Description: Stores telephone dial string x in memory location n . Dial the stored number using the command ATDS=n . MTPSR3-200...
Page 64
= 0 or 1 Defaults: Description: \X0 Respond to and discard XON/XOFF characters. Not supported—responds ERROR. Command: -C n Data Calling Tone Values: n = 0 or 1 Defaults: Description: -C0 Disable V.25 data calling tone. Enable V.25 data calling tone. MTPSR3-200...
Page 65
DSP checksum in RAM. Entering AT%T124<cr> tests the DSP56K code version and checksum running in internal ROM. Upon issuing this command the user may then issue ATI4<cr> to get DSP version or ATI1<cr> to get DSP checksum in ROM. MTPSR3-200...
Page 68
Backward Explicit Congestion Notification (BECN): A bit that tells you that a certain frame on a particular logical connection has encountered heavy traffic. The bit provides notification that congestion-avoidance procedures should be initiated in the opposite direction of the received frame. See also FECN (Forward Explicit Congestion Notification). MTPSR3-200...
Page 69
PABX or any residential telephone connects to the PSTN at a central office. Centrex: A multi-line service offered by operating telcos which provides, from the telco CO, functions and features comparable to those of a PBX for large business users. See also “Private Branch Exchange”, “Exchange”. MTPSR3-200...
Page 70
Data coming into a frame relay node is thus allowed to be sent across the interface to the specified “address”. The DLCI is confirmed and relayed to its destination, or if the specification is in error, the frame is discarded. MTPSR3-200...
Page 71
Errored Seconds (ES): Any second of operation that all 1.544M bits are not received exactly as transmitted. Contrast “Error Free Seconds”. Error Free Seconds (EFS): Any second of operation that all 1.544M bits are received exactly as transmitted. Contrast “Errored Seconds”. MTPSR3-200...
Page 72
Frame Relay specifications are defined by ANSI documents ANSI T1.602, T1.606, T1S1/90-175, T1S1/ 90-213, and T1S1/90-214. In using frame relay, blocks of information (frames) are passed across a digital network interface using a “connection number” that is applied to each frame to distinguish between individual frames. MTPSR3-200...
Page 73
IRQs are numbered so that the device issuing the IRQ can be identified, and so IRQs can be prioritized. ISA (Industry Standards Architecture) (pronounced “ice a”): The classic 8 or 16-bit architecture introduced with IBM’s PC-AT computer. MTPSR3-200...
Page 74
LDC is commonly called the point of presence (POP). Each LDC has a number of POPs, located throughout the country. The LDC is also called an IEC (Inter Exchange Carrier). Long Haul Communications: The type of phone call reaching outside of a local exchange (LE). MTPSR3-200...
Page 75
Dialing and various other “supervisory” signals are included in the signaling element. Contrast “In-band” signaling. Out of Frame (OOF): A T1 alarm condition that is logged on the loss of 2, 3 or 4 of 5 consecutive FT framing bits. MTPSR3-200...
Page 76
(PPM). 2. Transmissions of analog information in digital form through sampling and encoding the samples with a fixed number of bits. Pulse dialing: One of two methods of dialing a telephone, usually associated with rotary-dial phones. Compare with “tone dialing”. MTPSR3-200...
Page 77
(e.g., the user premises and the telco CO). Central office signals to the user premises can include ringing, dial tone, speech signals, etc. Signals from the user’s telephone can include off-hook, dialing, speech to far-end party, and on-hook signals. In-band signaling techniques include pulse and tone dialing. With common channel signaling, information is carried out-of- band. MTPSR3-200...
Page 78
T1 signal. Wide bandwidth signals take more than one time slot. Normal voice traffic or 56/64K bps data channels take one time slot. The T1 mux may use an internal or external T1 DSU; a “channel bank” device typically uses an external T1 CSU. MTPSR3-200...
Page 79
Virtual Circuit: A logical connection. Used in packet switching wherin a logical connection is established between two devices at the start of transmission. All information packets follow the same route and arrive in sequence (but do not necessarily carry a complete address). MTPSR3-200...
Page 80
Contrast “Red Alarm” and “Blue Alarm”. Zero Byte Time Slot Interchange (ZBTSI): A method for allowing 64K bps unrestricted user data (allowing all 0s in the user data). An alternative to (but not as popular as) B8ZS. MTPSR3-200...
Need help?
Do you have a question about the ProxyServer MTPSR3-200 and is the answer not in the manual?
Questions and answers