How To Correct Problems In The Machine - Clarke 00310S Operator's Manual

Rider scrubber rotary, cylindrical and boost (manual steering)
Hide thumbs Also See for 00310S:
Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
Insuffi cient water onto the brushes
The machine does not clean
satisfactorily
The squeegee does not dry the fl oor
The vacuum motor does not function
The machine does not start
The brush motors do not work
WARNING: To avoid damage to the fl oor,
the motor starts only when the machine is
traversing.
Clarke
®
Operator's Manual (EN) - Focus Rider

HOW TO CORRECT PROBLEMS IN THE MACHINE

CAUSE
The solution fl ow is not set
There is no water in the solution tank.
The solution fi lter is dirty.
A circuit breaker has tripped.
Insuffi cient fl ow.
The brushes are worn.
Need to use a different kind of brush/pad
The squeegee is dirty.
Recovery drain hose is not closed.
The suction hoses need to be cleaned.
The squeegee blades are worn.
The recovery tank is full.
The squeegee up/down switch in not in the low or
middle position.
The operator is not properly seated.
The key is not in the "ON position".
The charger is still connected.
The batteries are not charged or not connected
properly.
The circuit breaker has tripped.
The brush head unit is not down.
The batteries are not charged or not connected
properly.
Poor electrical connection at the brush head unit.
ENGLISH
ACTION
Make sure the solution fl ow is set.
Fill the solution tank.
Clean the solution fi lter.
Reset the circuit breaker.
Increase fl ow with solution switch.
Check the brushes and replace if necessary.
(the brushes have to be replaced when the bristles reach
approximately .59 inches (15mm height.)
Use a different kind of brush. For cleaning operations on
fl oors where the dirt proves to be particularly resistant,
we recommend using special brushes. See Accessories
page.
Clean the squeegee.
Close the drain plug.
Clean the vacuum hoses. See "Routine Maintenance"
section.
Replace/ or rotate the squeegee blades. See "Routine
Maintenance" section.
Drain recovery tank.
Put the squeegee in the low or middle position or repro-
gram "one touch".
The operator must be properly seated in the driving posi-
tion.
Turn the key to the "ON" position.
Remove the A/C cord from the wall.
Check to make sure the batteries are connected prop-
erly and charge if necessary.
Reset the circuit breaker.
Put the brush head unit down.
Check to make sure the batteries are connected prop-
erly and charge if necessary.
Connect the electrical connection at the brush head
unit.
Form No. 71171A
EN
- 27 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

00310c00311s00311c00312s00312c00317s ... Show all

Table of Contents