Rear Squeegee Blade Replacement; Squeegee Maintenance; Cleaning The Vac Hose - Clarke 00310S Operator's Manual

Rider scrubber rotary, cylindrical and boost (manual steering)
Hide thumbs Also See for 00310S:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
EN
Maintenance

Rear Squeegee Blade Replacement

If the rear squeegee blade is worn and does not dry the fl oor well,
follow this procedure:
1.
Remove the squeegee assembly from the machine.
2.
Remove the squeegee blade and inspect it.
3.
Rotate the squeegee blade to obtain a new cleaning edge.
Replace if necessary.
4.
Reinstall the squeegee blade.
5.
Reinstall the squeegee assembly on the machine.
6.
Readjust the settings on the squeegee as required (see
"How to Adjust Squeegee").

Squeegee Maintenance

The squeegee blade may be rotated for longer life.
Keep sharp corner on fl oor for best cleaning
results. See fi gure 40. To rotate follow this
procedure:
1.
Remove Clamp.
2.
Remove blade and rotate to new edge.
3.
Replace squeegee.
4.
Replace clamp.
Every 250 hrs (BOOST Only)
1.
Isolators are expected to last 250-1,000 hours depending on
the application.
2.
Replace lower isolators annually or after every 250 hours,
whichever comes fi rst.
Cleaning the Vacuum Hoses
Make sure the squeegee is over a suitable drain.
1.
Use a garden hose to fl ush through the recovery hoses.
2.
Side Squeegee - Position garden hose to the squeegee
side of the hose and fl ush thoroughly.
3.
Recovery Hose - Position water hose
inside recovery tank. Recovery hose is located behind
threaded lip (see fi gure 41, A). NOTE: Do not place hose
in vacuum intake tube (see fi gure 41, B), damage will
occur.
Page -26-
Form No. 71171A
revised 8/12
Figure 40
A
B
Figure 41
Clarke
®
Operator's Manual (EN) - Focus Rider

Advertisement

Table of Contents
loading

This manual is also suitable for:

00310c00311s00311c00312s00312c00317s ... Show all

Table of Contents