How To Correct Problems In The Machine - Clarke ultra speed Operator's Manual

Burnisher 120v & 240v with nema plug
Table of Contents

Advertisement

HOW TO CORRECT PROBLEMS IN THE MACHINE

Problem
The machine will not run.
The pressure gauge
indicator stays in the
red area.
The machine will not
start .
The pressure gauge
indicator stays in the
white area.
The brush warning light
illuminates.
The machine is vibrating
excessively.
Page - 22 -
Cause
The machine may not have
any power.
The power cord may be
damaged.
There is too much pad pressure.
The pad is worn or dirty.
There is too much pad pressure.
There is too much pad pressure.
The main switch is defective.
The circuit breaker is defective.
The machine may have no power.
The pad pressure needs
adjusting.
The carbon brushes need
replacing.
The pad is not installed
correctly.
The pad is worn or damaged.
The pad is defective.
Action
Make sure the machine is connected to
the correct voltage and frequency and
that all connections are tight or,
Make sure the machine is plugged in.
Contact an authorized service person
Decrease the pad pressure
Clean the pad. If the pad is worn, replace it.
Decrease the pad pressure.
Decrease the pad pressure.
Contact an authorized service person.
Contact an authorized service person.
Make sure the machine is connected to
the correct voltage and frequency and
that all connections are tight or,
Make sure the machine is plugged in.
Verify a pad is on the machine.
Increase the pad pressure.
Contact an authorized service person.
Remove the pad. Install the pad correctly.
Center the pad properly.
Install a new pad.
Inspect and install a new pad.
Operator's Manual - Ultra Speed Burnisher
Clarke
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultra speed burnisher

Table of Contents