Santa Fe Pellet Stove
G. Through The Wall
Horizontal termination cap must be a minimum of 6 inches.
(152mm) from the wall. Approved for mobile home instal-
lations. Must use 3 or 4 inch (76-102mm) "L" or "PL" listed
pellet venting or listed double wall pipe and a Quadra-Fire
Outside Air Kit in mobile homes.
NOTICE:
Please note that while the minimum clearance for the
termination cap is 6 inches (152mm) there is the possi-
bility of soot build-up around the termination area. If this
occurs we suggest to move the termination further away
from the house to prevent it.
Straight Out
Figure 17.1
45 Degree
Figure 17.2
May 12, 2014
2 in.
(51mm)
Minimum
6 in.
(152mm)
Minimum
From Glass
Non-combustible Hearth Pad
Illustration shows venting going in both directions.
Choose which one is best for your installation.
Wall
Thimble
6 in.
(152mm)
Minimum
2 in.
(51mm)
Minimum
7050-128G
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365
CAUTION
We strongly recommend that you DO NOT
DOWNWARD VENT.
The following may occur:
• The appliance will not vent properly
• Smoke spillage in the house
• Excessive sooting
Horizontal
Wall
Termination
Thimble
Cap
6 in.
(152mm)
Minimum
6 in. (152mm)
Minimum
2 in. (51mm)
Minimum
R
Page 17