Quadra-Fire SANTAFE-MBK Installation Manual

Quadra-Fire SANTAFE-MBK Installation Manual

Hide thumbs Also See for SANTAFE-MBK:

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
SANTA FE PELLET STOVE
Model(s):
SANTAFE-MBK
CAUTION
Tested and approved for wood pellets and shelled
corn only.. Burning of any other type of fuel voids your
warranty.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and na-
tional codes and regulations.
• Consult local building, fi re offi cials or authorities having juris-
diction about restrictions, installation inspection, and permits.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
Tested and
Portland
O-T L
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
If the information in these instruc-
tions is not followed exactly, a
fi re could result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other fl ammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafi re.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafi re.com
7050-145E
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
NOTE
August 3, 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SANTAFE-MBK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Quadra-Fire SANTAFE-MBK

  • Page 1 Model(s): • Do not store or use gasoline or other fl am- SANTAFE-MBK mable vapors and liquids in the vicinity of this or any other appliance. • Do not overfi re - If heater or chimney con- nector glows, you are overfi...
  • Page 2: Table Of Contents

    SANTA FE FREESTANDING Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. •...
  • Page 3: Important Safety Information

    B. BTU & Effi ciency Specifi cations Fire Risk Hearth & Home Technologies disclaims any The Quadra-Fire Sante Fe Pellet Heater meets the U.S. responsibility for, and the warranty will be voided by, Environmental Protection Agency’s emission limits for pellet the following actions: heaters sold after May 15, 2015.
  • Page 4: Getting Started

    SANTA FE FREESTANDING Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. •...
  • Page 5: Thermostat Wall Control Location

    SANTA FE FREESTANDING B. Thermostat Wall Control Location WARNING The thermostat wall control’s location will have some affect on the appliance’s operation. Hearth & Home Technologies disclaims any responsibility for, and the warranty will be • Maximum wire length from appliance is 100 feet (30.48m) voided by, the following actions: continuous un-spliced wire.
  • Page 6: Install Checklist

    Installer: Dealer/ Distributor Phone #: Serial #: Model (circle one): SANTAFE-MBK WARNING! Risk of Fire or Explosion! Failure to install fi replace according to these instructions can lead to a fi re or explosion. Appliance Install IF NO, WHY? Verifi ed clearances to combustibles. (Pg. 8) Fireplace is leveled and liner is secured to appliance.
  • Page 7: Dimensions And Clearances

    SANTA FE FREESTANDING Dimensions and Clearances A. Appliance Dimensions 25-1/2 in. (658mm) 12-3/4 in. (324mm) 28-11/16 in. (729mm) 21-1/4 in. (540mm) Figure 7.1 - Top View Figure 7.2- Front View 28-1/8 in. (715mm) 25-11/16 in. (653mm) 3-3/4 in. (95mm) 2-1/2 in. (64mm) 28-3/4 in.
  • Page 8: Clearances To Combustibles (Ul And Ulc)

    SANTA FE FREESTANDING B. Clearances to Combustibles (UL and ULC) Alcove Installation Inches Millimeters Minimum Alcove Height 1092 Minimum Alcove Side Wall Minimum Alcove Width Maximum Alcove Depth C. Hearth Pad Requirements (UL and ULC) Use a non-combustible fl oor protector, extending beneath appliance and to the front, sides and rear as indicated.
  • Page 9: Vent Information

    SANTA FE FREESTANDING Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Figure 9.1 Termination Cap Air Supply Inlet Restricted Area Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 10: Avoiding Smoke And Odors

    SANTA FE FREESTANDING B. Avoiding Smoke and Odors • Maintain specifi ed clearances to windows, doors and air inlets, including air conditioners. Negative Pressure, Shut-Down and Electrical Power Failure • Vents should not be placed below ventilated soffi ts. To reduce the probability of back-drafting or burn-back in Run the vent above the roof.
  • Page 11: Draft

    (76-152mm) Top Vent Offset Adapter, use Listed double wall • Clearance of a termination cap above electrical service fl ue connector. A Quadra-Fire Outside Air Kit must be used with will be 12 inches (305mm) minimum. manufactured home installations.
  • Page 12: Equivalent Feet Of Pipe

    SANTA FE FREESTANDING G. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size. Vent surfaces get HOT, can cause burns if Figure 12.1. touched.
  • Page 13: Pellet Venting Charts

    SANTA FE FREESTANDING I. Pellet Venting Charts WARNING The maximum horizontal venting allowed with no vertical vent- ing attached is 48 inches (1219mm) including one 90° elbow Fire Risk or two 45° elbows. This is our recommended horizontal vent- • Only LISTED venting components may be used. ing installation.
  • Page 14: Venting Systems

    SANTA FE FREESTANDING Venting Systems A. Alcove Figure 14.1 Minimum* Maximum Inches Millimeters Inches Millimeters Height 1092 Width Depth To Side Wall *All minimums listed are to a combustible surface. NOTE: • Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY.
  • Page 15: Through The Wall

    (152mm) from the wall. Approved for mobile home installa- CAN/CSA-B365 tions. Must use 3 or 4 inch (76-102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and a Quadra-Fire NOTICE: Outside Air Kit in mobile homes. Please note that while the minimum clearance for the ter- mination cap is 6 inches (152mm) there is the possibility of soot build-up around the termination area.
  • Page 16: Vertical Into Existing Class A Chimney

    All three installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and Quadra-Fire Outside Air Kit in mobile homes. Single wall pipe is Flashing approved for residential installations only.
  • Page 17: Masonry

    SANTA FE FREESTANDING WARNING Fire Risk Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be a minimum 6 inch (152mm) UL103 HT. F. Masonry Fireclay flue Concrete Cap Liner with Airspace Flashing...
  • Page 18: Appliance Set-Up

    SANTA FE FREESTANDING Appliance Set-Up A. Outside Air Kit Instructions CAUTION Parts Included in Kit: 1 piece of 2 inch x 3 foot fl ex hose, Never draw outside combustion air from: 2 hose clamps, 1 air intake channel1 collar assembly, 1 ter- •...
  • Page 19: Top Vent Adapter Installation

    SANTA FE FREESTANDING C. Top Vent Adapter Installation 3 to 3 inch Top Vent Adapter 3 to 6 inch Top Vent Offset Adapter Installing the Top Vent Adapter Drill Holes in back of stove and secure with 4 Put a layer of high temperature silicone on the 3 inch screws, 2 on each side (76mm) exhaust outlet.
  • Page 20: Optional Log Set Placement Instructions

    SANTA FE FREESTANDING E. Optional Log Set Placement Instructions F. Thermostat Installation 2 Piece Log Set Installation There is a 4 screw terminal block located on the back Open door to expose the fi rebox. lower left corner of the stove directly above the power Install the left log fi...
  • Page 21 SANTA FE FREESTANDING F. Thermostat Installation (continued) Battery Installation and Replacement The appliance comes standard with a wall thermostat and 25’ of wire. If you need to run more than 25’ make sure you use NOTE: 2 AA batteries are included with the thermostat a continuous strand of 18 to 22 gauge thermostat wire.
  • Page 22: Optional Nickel Or Black Nickel Grille

    SANTA FE FREESTANDING G. Optional Nickel or Black Nickel Grille Grille Bracket Cover (shipped flat from factory) Heat Exchanger Rods Finger bend into position after grilles are installed on appliance Insert heat exchanger rods through holes on second grille. Install in flat position Bend after grilles installed Install bottom 3 grilles before installing single top grille...
  • Page 23: Mobile Home Installation

    SANTA FE FREESTANDING Mobile Home Installation You must use a Quadra-Fire Outside Air Kit CAUTION for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME An outside air inlet must be provided for the combustion air and FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED must remain clear of leaves, debris, ice and/or snow.
  • Page 24: Accessory List

    SANTA FE FREESTANDING Accessory List SANTAFE-MBK Service Parts Beginning Manufacturing Date: June 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 25 SANTA FE FREESTANDING August 3, 2015 7050-145E...
  • Page 26 SANTA FE FREESTANDING 7050-145E August 3, 2015...
  • Page 27 SANTA FE FREESTANDING August 3, 2015 7050-145E...
  • Page 28 Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL...

Table of Contents