SANTA FE PELLET APPLIANCE
MODEL:
SANTAFE-C
CAUTION
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, fire officials or authorities
having jurisdiction about restrictions, installation
inspection, and permits.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
R
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal injury,
or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void your
warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down. Hot glass will
cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as fireplace.
Alert children and adults to hazards of
high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
NOTE: To obtain a French translation of this
manual, please contact your dealer or visit
www.quadrafire.com
REMARQUE : Pour obtenir une traduction française de
ce manuel, s'il vous plaît contacter votre
revendeur ou visitez
7050-801E
WARNING
WARNING
CAUTION
www.quadrafire.com
09/20

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire SANTA FE SANTAFE-C

  • Page 1 Installation Manual Installation & Appliance Set-Up INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is SANTA FE PELLET APPLIANCE not followed exactly, a fire could result causing property damage, personal injury, or death.
  • Page 2: Table Of Contents

    G. Pipe Selection Chart ......16 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7050-801E...
  • Page 3: Important Safety Information

    SANTA FE FREESTANDING Important Safety Information A. Appliance Certification B. BTU & Efficiency Specifications Model Santa Fe Pellet Appliance Emissions Report 0061PM077E Number: Laboratory OMNI Test Laboratories, Inc. EPA Certification #: 175-19 Report No. 061-S-77d-6.2 EPA Certified Emissions: 1.1 grams per hour Type Solid Fuel Room Appliance/Pellet Fuel *LHV Tested Efficiency: 70.4% Burning Type...
  • Page 4: Glass Specifications

    SANTA FE FREESTANDING C. Glass Specifications WARNING This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. Fire Risk. Hearth & Home Technologies disclaims any D. Electrical Rating responsibility for, and the warranty will be 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps voided by, the following actions:...
  • Page 5: Getting Started

    SANTA FE FREESTANDING Install Guide Getting Started A. Design, Installation & Location Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: Considerations • Windows 1. Appliance Location • Air Intakes • Air Conditioner NOTICE: Check building codes prior to installation. •...
  • Page 6: Thermostat Wall Control Location

    SANTA FE FREESTANDING B. Thermostat Wall Control Location WARNING The thermostat wall control’s location will have some affect on the appliance’s operation. Risk of Fire! • Maximum wire length from appliance is 100 • Damaged parts could impair feet (30.48m) with continuous non-spliced wire. Recommended 20 gauge wire, solid copper .
  • Page 7: Install Checklist

    SANTA FE FREESTANDING E. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. __________________________________________________________________________ Customer: ______________________________________________________________________ Date Installed: _______________________________________________________________________ Lot/Address:...
  • Page 8: Dimensions And Clearances

    SANTA FE FREESTANDING Dimensions and Clearances A. Appliance Dimensions 2-1/2 in (64mm) 12-3/4 in 3-3/4 in (324mm) 12-3/4 in (95mm) (324mm) 6-7/8 in (175mm) 21-1/4 in 21-1/4 in (540mm) (540mm) Figure 8.1 - Top View Figure 8.3 - Top View with Top Vent Adapter (TPVNT-2) and Offset Adapter (812-3570).
  • Page 9 SANTA FE FREESTANDING 21 in (533mm) 28-3/4 in (730mm) 26-7/8 in (653mm) 16-3/4 in (427mm) 18-1/4 in (464mm) Figure 9.1 -Side View Figure 9.3 - Side View with Top Vent Adapter (TPVNT-2) and Offset Adapter (812-3570). 28-1/2 in (722mm) 24-1/2 in (621mm) 26-3/4 in 22-3/4 in...
  • Page 10: Clearances To Combustibles (Ul And Ulc)

    SANTA FE FREESTANDING B. Clearances to Combustibles (UL and ULC) Installations with: TPVNT-2 Top Vent Adapter w/Heat Shield & Clean-out TPVNT-6 Top Vent Adapter with Clean-out 812-3570 (3” to 6”) Offset Adapter 811-0720 (3” to 4”) Offset Adapter Horizontal Through the Wall Inches Millimeters Vertical Installation...
  • Page 11: Hearth Pad Requirements (Ul And Ulc)

    SANTA FE FREESTANDING C. Hearth Pad Requirements (UL and ULC) USA INSTALLATIONS: A non-combustible floor protection is recommended extending beneath the flue pipe when EMBER PROTECTION: It is necessary to install a Type I installed with horizontal venting or under the Top Vent floor protector.
  • Page 12: Alcove

    SANTA FE FREESTANDING D. Alcove Figure 12.2 Figure 12.1 Minimum* Maximum Inches Millimeters Inches Millimeters Height 1092 Width Depth D To Side Wall Table 12.1 *All minimums listed are to a combustible surface. NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.
  • Page 13: Vent Information

    SANTA FE FREESTANDING Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Termination Cap Air Supply Inlet Gas Meter Restricted Area Figure 13.1 All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 14: Avoiding Smoke And Odors

    SANTA FE FREESTANDING B. Avoiding Smoke and Odors Vent Configurations When installing a pellet appliance with a horizontal vent Negative Pressure, Shut-Down and Electrical configuration the frequency of power outages should Power Failure be considered: To reduce the probability of back-drafting or burn-back •...
  • Page 15: Negative Pressure

    • Imbalances of the HVAC air handling system or the 3 to 6 inch (76-152mm) Top Vent Offset Adapter, • Upper level air leaks such as: use Listed double wall flue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home Recessed lighting installations.
  • Page 16: Equivalent Feet Of Pipe

    SANTA FE FREESTANDING F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size (Figure 16.1). Vent surfaces get HOT, can cause burns if touched.
  • Page 17: Venting Systems

    “PL” Listed pellet venting or Listed double wall pipe and a NOTICE: Please note that while the minimum clearance Quadra-Fire Outside Air Kit in mobile homes. for the termination cap is 6 inches (152mm) there is the possibility of soot build-up around CAUTION the termination area.
  • Page 18: Vertical Into Existing Class A Chimney

    SANTA FE FREESTANDING B. Vertical into Existing Class A Chimney All three installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Rain Cap Listed pellet venting or Listed double wall pipe and Quadra- Fire Outside Air Kit in mobile homes.
  • Page 19: Masonry

    SANTA FE FREESTANDING WARNING Fire Risk Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be a minimum 6 inch (152mm) UL103 HT. E. Masonry Fireclay flue Concrete Cap Liner with Airspace Flashing...
  • Page 20: Appliance Set-Up

    SANTA FE FREESTANDING Appliance Set-Up A. Outside Air Kit Instructions 1. Measure distance from floor to air vent opening in appliance and mark location on wall. Use a saw to cut opening in wall. Cut a 2-1/2 to 3 inch (64-76mm) CAUTION opening on inside wall and a 3 to 3-1/2 inch (76-89mm) opening on outside of house.
  • Page 21: Top Vent Adapter Installation

    SANTA FE FREESTANDING B. Top Vent Adapter Installation C. Rear Vent & Rear Vent to Top Vent Adapter Installation 3 to 3 inch Top Vent Adapter 1. Put a layer of high temperature silicone on the 3 inch 3 to 6 inch Top Vent Offset Adapter (76mm) exhaust outlet.
  • Page 22: Optional Log Set Placement Instructions

    SANTA FE FREESTANDING E. Optional Log Set Placement Instructions 1. Separate the body of the thermostat from the mounting plate by gently pulling the two pieces apart 2 Piece Log Set Installation (Figure 22.1) 1. Open door to expose the firebox. 2.
  • Page 23: Mobile Home Installation

    SANTA FE FREESTANDING Mobile Home Installation You must use a Quadra-Fire Outside Air Kit for CAUTION installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE 1. An outside air inlet must be provided for the HOME FLOOR, WALL AND CEILING/ROOF MUST combustion air and must remain clear of leaves, debris, ice and/or snow.
  • Page 24: Reference Materials

    SANTA FE FREESTANDING Reference Materials A. Service and Maintenance Log Date of Service Performed By Description of Service 7050-801E 09/20...
  • Page 25 SANTA FE FREESTANDING Date of Service Performed By Description of Service 7050-801E 09/20...
  • Page 26: Accessories List

    IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor. SANTA FE FREESTANDING at Depot ITEM...
  • Page 27 SANTA FE FREESTANDING SANTAFE-C Service Parts Beginning Manufacturing Date: April 2019 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 28 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL •...

Table of Contents