Motor Testing

NOTE: For this procedure, refer to FIGURE 3.2.
1. On the 4-pin motor connector, locate
the two contacts in the RED and
BLACK housings.
2. Set the digital multimeter to measure
resistance (ohms).
3. Measure the resistance between the
two motor contacts.
NOTE: A normal reading is between .5 and 5
ohms. A reading of 0 ohms or in excess of 15
ohms indicates a problem. High readings are
generally caused by bad connections and/or
damaged brushes. Contact Invacare.
Part No. 1125075
SECTION 3—SAFETY INSPECTION/TROUBLESHOOTING
Charger
Digital
Port
Voltmeter
BATTERY
QUALITY
0 to 2 volts
Good
2 to 2.5 volts Poor
2.5 or more
Bad
FIGURE 3.1 Field Load Test
31
Cap
4 Pin Motor
Connector
FIGURE 3.2 Motor Testing
Motor
Pronto® Series