LUT data communication
LUTB
(For Blue)
TPN
Test pattern
RF
RCT FVAL Type
CM
Center Marker
CMTX
Color Matrix
MGRR
R_R_MATRIX_GAIN
3
MGRG
R_G_MATRIX_GAIN
3
MGRB
R_B_MATRIX_GAIN
3
MGGR
G_R_MATRIX_GAIN
3
MGGG
G_G_MATRIX_GAIN
3
MGGB
G_B_MATRIX_GAIN
3
MGBR
B_R_MATRIX_GAIN
3
MGBG
B_G_MATRIX_GAIN
3
MGBB
B_B_MATRIX_GAIN
3
NRC
Noise reduction
NRS
Noise reduction threshold
TMS
Temperature sensor
G – Saving and loading data in EEPROM
Load settings from
LD
camera EEPROM
Save settings to
SA
camera EEPROM
EA
EEPROM area request
!!
Do not try to use commands not shown in this list.
AT-200CL
LUTB=[Param.]<CR><L
F>
LUTB?<CR><LF>
TPN=[Param.]<CR><LF
>
TPN?<CR><LF>
RF=[Param.]<CR><LF>
RF?<CR><LF>
CM=[Param.]<CR><LF>
CM?<CR><LF>
CMTX=[Param.]<CR><L
F>
CMTX?<CR><LF>
MGRR3=,[Param.]<CR>
<LF>
MGRR3?<CR><LF>
MGRG3=[Param.]<CR>
<LF>
MGRG3?<CR><LF>
MGRB3=[Param.]<CR>
<LF>
MGRB3?<CR><LF>
MGGR3=[Param.]<CR>
<LF>
MGGR3?<CR><LF>
MGGG3=[Param.]<CR>
<LF>
MGGG3?<CR><LF>
MGGB3=[Param.]<CR>
<LF>
MGGB3?<CR><LF>
MGBR3=[Param.]<CR>
<LF>
MGBR3?<CR><LF>
MGBG3=[Param.]<CR>
<LF>
MGBG3?<CR><LF>
MGBB3=[Param.]<CR>
<LF>
MGBB3?<CR><LF>
NRC=[Param.]<CR><LF
>
NRC?<CR><LF>
NRS=[Param.]<CR><LF
>
NRS?<CR><LF>
TMS?<CR><LF>
LD=Param.<CR><LF>
SA=Param.<CR><LF>
EA?<CR><LF>
- 37 -
transfer by a serial method.
The number of the data is 512.
Param: 0 to 8191
0=OFF
1 to 15 pattern
0=Camera Link Standard
1=JAI Standard
Upper 4bit
Center marker RGB Indicate
Bit6
bit5
bit4
R-Ch G-Ch B-Ch
1:on
1:on
1:on
0:off
0:off
0:off
Lower 4bit
0=Normal Mode, 1=Vertical Bar
2=Horizontal Bar ,3=Both
0=Linear
1=sRGB
2=Adobe RGB
3=User
-2048 to 2047
-2048 to 2047
-2048 to 2047
-2048 to 2047
-2048 to 2047
-2048 to 2047
-2048 to 2047
-2048 to 2047
-2048 to 2047
0=FF
1=ON
0 to 255
-880 to 2400
0=Factory data
1=User 1 area
2=User 2 area
3=User 3 area
1=User 1 area
2=User 2 area
3=User 3 area
0=Factory data
1=User 1 area
2=User 2 area
3=User 3 area
0=FF, 255=max
/16 -= ℃
(-55 to 150℃)
Latest used data
defa. at power up
Parameter = 0 is
not allowed
Return latest used
area