AGC
AASX
Window Size X
AGC
AASY
Window Size Y
AGC
AAOX
Window offset X
AGC
AAOY
Window offset Y
AGCS
AGC Speed
AGCF
AGC Reference
SDM
Shading Correction Mode
Recalibrate Shading
RS
Correction
SDTH
Shading Threshold
KN
Knee On/Off
KSR
Knee Slope - Red
KSM
Knee Slope - Green
KSB
Knee Slope - Blue
KPR
Knee Point - Red
KPM
Knee Point - Green
KPB
Knee Point - Blue
SP00
Setup -Green
SPR0
Setup -Red
SPB0
Setup -Blue
F – AWB,LUT and other
WB
White Balance Mode
AW
One-push AWB
White Balance
WASX
Window Size X
White Balance
WASY
Window Size Y
White Balance
WAOX
Window offset X
White Balance
WAOY
Window offset Y
Request the Result of
AWRS
One Push AWB
LUTC
LUT Control
LUT data communication
LUTR
(For Red)
LUT data communication
LUTG
(For Green)
AT-200CL
AASX=[Param.]<CR><LF>
AASX?<CR><LF>
AASY=[Param.]<CR><LF>
AASY?<CR><LF>
AAOX=[Para.]<CR><LF>
AAOX?<CR><LF>
AAOY=[Para.]<CR><LF>
AAOY?<CR><LF>
AGCS=[Param]<CR><LF>
AGCS?<CR><LF>
AGCF=[Para.]<CR><LF>
AGCF?<CR><LF>
SDM=[Param.]<CR><LF>
SDM?<CR><LF>
RS=[Param1],[Param2]<
CR><LF>
SDTH=[Param.]<CR><L
F>SDTH?<CR><LF>
KN=[Param.]<CR><LF>
KN?<CR><LF>
KSR=[Param]<CR><LF>
KSR?<CR><LF>
KSM=[Param]<CR><LF>
KSM?<CR><LF>
KSB=[Param]<CR><LF>
KSB?<CR><LF>
KPR=[Param]<CR><LF>
KPR?<CR><LF>
KPM=[Param]<CR><LF>
KPM?<CR><LF>
KPB=[Param.]<CR><LF>
KPB?<CR><LF>
SP00=[Param.]<CR><LF>
SP00?<CR><LF>
SPR0=[Param.]<CR><L
F>
SPR0?<CR><LF>
SPB0=[Param.]<CR><L
F>
SPB0?<CR><LF>
WB=[Param.]<CR><LF>
WB?<CR><LF>
AW=[Param.]<CR><LF>
WASX=[Param.]<CR><
LF>
WASX?<CR><LF>
WASY=[Param.]<CR><
LF>
WASY?<CR><LF>
WAOX=[Param.]<CR><
LF>
WAOX?<CR><LF>
WAOY=[Param.]<CR><
LF>
WAOY?<CR><LF>
AWRS?<CR><LF>
LUTC=[Param.]<CR><L
F>
LUTC?<CR><LF>
LUTR=[Param.]<CR><L
F>
LUTR?<CR><LF>
LUTG=[Param.]<CR><L
F>
LUTG?<CR><LF>
- 36 -
1 to 8
1 to 8
0 to 7
0 to 7
0=slow
1=standard
2=fast
512 to 14240
0=Off,
1=Factory Shading.
2=User1,
3=User2
Param1:0=User1,1=User2
Param2:0=Flat, 1=Color
16384 to 65535
0=Off, 1=On
0 to 16383
0 to 16383
0 to 16383
0 to 4095
0 to 4095
0 to 4095
±128
±128
±128
0=Manual/One push AWB 1=Continuous
2=4000K
3=4600K
4=5600K
1=Activates one-push AWB
1 to 8
1 to 8
0 to 7
0 to 7
0=Complete. 1=Too Bright.
3=Timeout Error. 4=Busy
6= Trig is not set as Normal.
0=off, 1=0.45γ,2=0.6γ,3=LUT
transfer by a serial method.
The number of the data is 512.
Param: 0 to 8191
transfer by a serial method.
The number of the data is 512.
Param: 0 to 8191
AGC tracking
speed setting
Default=standard
AGC Reference
Level at 14bit
X1 at 16383
X1 at 16383
X1 at 16383
2=Too dark.
5=Limit.