Factory Defaults:
settings to the initial values specified by the manufacturer.
If you want the factory default settings to become the power up defaults, first
click the Factory Defaults button, then click the Save Settings button.
Reset Camera:
The Reset Camera button restarts the camera
software.
Test-Pattern:
A Test-Pattern mode is provided to verify
camera electronics. The Test-Pattern mode will not persist
over a power cycle.
Off: No test-pattern is provided in this mode.
This is the normal mode for viewing thermal
imagery.
Ramp: In this ramp mode, the test pattern shown
below and in the Color/LUT section that follows is
provided at the analog and digital data channels.
pix(0,0) = 0
Figure 3-5: Ramp test pattern example for Top Portion of Tau Ramp Image
(Digital values shown apply to the optional 14-bit digital data stream.)
The above ramp pattern repeats 19 times in the complete 320 × 256 image.
Note
The ramp test pattern is intended primarily for verifying the output of the digital data channel.
The pattern will not necessarily look as shown above when displayed on an analog video
monitor, particularly if an Automatic Gain Control (AGC) mode other than Automatic is
selected. The above image is a horizontal slice of the full displayed image.
Gain Mode:
The Tau camera has two gain ranges:
High gain mode is designed to maximize contrast for imaging applications.
Low gain mode has lower contrast but a higher dynamic range and is designed for
viewing hot targets.
Auto gain mode allows the Tau camera to switch between Low and High gain mode
based on the scene being viewed, Auto mode is controlled by the Gain Switch Values
in the Thermal tab. See "Thermal Tab" on page 3-28.
TAU-0035-00-10, version 150
The Factory Defaults button restores the camera's
June 2011
3—Basic Operation of the Tau and GUI
pix(25,408) = 16383
pix(25,409) = 0
pix(639,0)
3-15

Hide quick links: