Comtech EF Data Radyne RCS11 Installation And Operation Manual page 103

1:1 redundancy switch
Table of Contents

Advertisement

RCS11 1:1 Redundancy Switch
Opcode: <2089h>
Query Response Data Field (4 Bytes):
<1>
External Alarm Masks
<1>
Switch Alarm Masks
<2>
Spare Current Alarms
Opcode: <2289h>
Command Data Field (4 Bytes):
<1>
External Alarm Masks
<1>
Switch Alarm Masks
<2>
Spare Current Alarms
MN-RCS11 – Revision 9
Query RCS11 Switch Alarms Mask
Bit 0: 1 = Mod A Alarm Enabled
Bit 1: 1 = Force Mod A Alarm Enabled
Bit 2: 1 = Demod A Alarm Enabled
Bit 3: 1 = Force Demod A Alarm Enabled
Bit 4: 1 = Mod B Alarm Enabled
Bit 5: 1 = Force Mod B Alarm Enabled
Bit 6: 1 = Demod B Alarm Enabled
Bit 7: 1 = Force Demod B Alarm Enabled
Bit 0: 1 = Switch Power 1 Alarm Enabled
Bit 1: 1 = Switch Power 2 Alarm Enabled
Bit 2: 1 = Switch Firmware Error Enabled
Bit 3: 1 = Switch NV Alarm
Bit 4: 1 = Switch Internal Alarm Enabled
Bit 5..7: unused, return 0
Command RCS11 Switch Alarms Masks
Bit 0: 1 = Mod A Alarm Enabled
Bit 1: 1 = Force Mod A Alarm Enabled
Bit 2: 1 = Demod A Alarm Enabled
Bit 3: 1 = Force Demod A Alarm Enabled
Bit 4: 1 = Mod B Alarm Enabled
Bit 5: 1 = Force Mod B Alarm Enabled
Bit 6: 1 = Demod B Alarm Enabled
Bit 7: 1 = Force Demod B Alarm Enabled
Bit 0: 1 = Switch Power 1 Alarm Enabled
Bit 1: 1 = Switch Power 2 Alarm Enabled
Bit 2: 1 = Switch Firmware Error Enabled
Bit 3: 1 = Switch NV Alarm Enabled
Bit 4: 1 = Switch Internal Alarm Enabled
Bit 5..7: unused, 0 filled
RCS11 Remote Communications
1 = Enabled, 0 = Masked Off
1 = Enabled, 0 = Masked Off
Always 0
1 = Enabled, 0 = Masked Off
1 = Enabled, 0 = Masked Off
0 filled
B–9

Advertisement

Table of Contents
loading

Table of Contents