Comtech EF Data Radyne RCS11 Installation And Operation Manual page 101

1:1 redundancy switch
Table of Contents

Advertisement

RCS11 1:1 Redundancy Switch
When transmitting a packet at 9600 baud, the Remote M&C should ensure
that the timeout value between characters does not exceed the time it takes to
transmit 200 characters (
Regular Commands
Opcode <2000h>
Query Response Data Field (1 byte):
<1>
Device Identification
Opcode <2080h>
Query Response Data Field (19 bytes):
<1>
Device Firmware Version MSB
<1>
Device Firmware Version LSB
<10>
Device Firmware Name
<7>
Device Firmware Release Date
Opcode <2280h>
Command Data Field (2 bytes):
<1>
Unlock Code 1
<1>
Unlock Code 2
Opcode <2083h>
Query Response Data Field (1 byte):
<1>
Backup Configuration
Opcode <2084h>
Query Response Data Field (1 byte):
<1>
Backup Mode
Opcode <2284h>
Command Data Field (1 byte):
<1>
Backup Mode
Opcode <2085h>
Query Response Data Field (2 bytes):
<1>
Mod Backup state
<1>
Demod Backup State
MN-RCS11 – Revision 9
IMPORTANT
200 msec). If this timeout value is exceeded, the
equipment will timeout.
Query RCS11 Device Identification
Query RCS11 Device Firmware Version
Command RCS11 Load Factory Defaults
Query RCS11 Backup Configuration
Query RCS11 Backup Mode
Command RCS11 Backup Mode
Query RCS11 Backup State
1 = B online
2 = <none or unknown>
RCS11 Remote Communications
26 decimal for RCS11
binary number, implied decimal point
binary number, implied decimal point
null terminated string
null terminated string
0x55
0xAA
0 = Modem (Coupled)
1 = Mod Only
2 = Demod Only
3 = Mod/Demod (Uncoupled)
0 = Manual
1 = Automatic
2 = <unknown>
0 = Manual
1 = Automatic
0 = A online
0 = A online
B–7