No-Shutter Mode With External Trigger - JAI LT-400CL User Manual

3cmos high speed color line scan camera
Table of Contents

Advertisement

EEN
LVAL
DVAL
Data
Fig.32
6.4.2

No-shutter mode with external trigger

In this mode, the exposure time is directly proportional to the line rate. The line rate is
generated externally by a trigger signal. This mode is used when an external trigger signal
is available, e.g. from an encoder, and the scan rate can be controlled by this signal. The
camera can accept an external trigger through the Camera Link connector or though the
12-pin Hirose connector.
To use this mode:
Set function
Trigger mode, No-shutter TR=0
Trigger origin, external
Trigger input
Important note:
 When the one-push white balance has been initiated and the rear panel LED shows
orange, the camera must receive continuous external trigger pulses corresponding to
the frequency and duty cycle used in the application.
 Minimum trigger interval
Scan mode
Full/Binning
Sub-sampling/windowing
 Minimum trigger pulse width
Trigger input via
Camera link
Hirose 12-pin
LT-400CL
1496clk
896clk
16clk
AP
No-shutter /Sub-sampling and Window/ Internal
Trigger input via
Camera link
Hirose 12-pin
Camera link
Hirose 12-pin
Minimum trigger pulse width
500 ns
5µs
24
2048clk
16clk
AP204
TG=1
TI=0 or 1
Minimum interval (µs)
62.3
66.8
37.0
41.5