Port
Transport Usage
69
UDP
TFTP Server, used for firmware upgrades
80
TCP
HTTP data. Value is user definable; the default is 80. Used to
communicate between the web browser and the Enterprise Controller
554
TCP
Real-time streaming protocol (RTSP) server.
5432
UDP
Enterprise Controller outgoing and incoming control messages. Value
is user definable; the default is 5432. Only used on the device acting as
controller to communicate with other VN-Matrix devices
5555
TCP
Old XML interface and old VN-Matrix recorder software application. No
longer used.
9998
TCP
Command Line Interface (CLI) messages. Used to telnet to the
controller for sending text-based control commands.
9999
TCP
Deprecated: Old remote control server, replaced by CLI (port 9998).
23
TCP
Telnet (can be disabled).
161
UDP
Used for simple network management protocol (SNMP) alarm access.
199
TCP
Used for simple network management protocol (SNMP) alarm access.
4002
TCP
Source stream information. Used to telnet to the VN-Matrix decoder to
view information about the source it is decoding.
5002
TCP
Serial port bidirectional protocol (not data channel streaming).
6666
TCP
Keyboard and mouse forwarding.
7777
UDP
Upgrade daemon, local access only.
8000-8098
UDP
RTP unicast or RTP multicast audio, video, whiteboard, and data
(even)
streams. Controller selects port number, starting at 8000. This is the
port number of the destination (receiver).
8001-8099
UDP
RTCP channel for audio, video, whiteboard, and data streams.
(odd)
Grouped with the even-numbered stream (8000 with 8001, 8002 with
8003, and so on). This is the port number of the destination (receiver).
8000
TCP
Video streams. This is the port number of the source (sender).
8100
TCP
Audio streams. This is the port number of the source (sender).
8200
TCP
Whiteboard streams. This is the port number of the source (sender).
8201
TCP
Data streams. This is the port number of the source (sender).
9000
TCP
HSI interface if using ThorDebug.
9001
UDP
VN-Matrix outgoing and incoming control messages. Communicates
with port 5432 (or the user-defined port number) on the Enterprise
Controller.
9002
UDP
Default port for collecting UDP traffic for data-transport. Value is
user-definable.
9996
TCP
HLI server port.
9997
TCP
Annotation server port.