Purge And Leak Test The Gas Line; Pilot Flame Inspection - Travis Industries DVL EF Insert Owner's Manual

Table of Contents

Advertisement

2 0
!
We recommend you purge the gas line at this time (with the glass removed). This allows gas to be
detected once it enters the firebox, ensuring gas does not build up.
3
Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot (see
page 23).
Warning: When lighting or re-lighting the pilot, the glass must be removed (see
page 23 for the full set of instructions on starting the pilot).
4
Replace the glass (see page 17). Start the main burner. Leak test all gas joints again.
5
Install the faceplate following the instructions included with the face (shut off the insert if necessary).
!
ACID WASH WARNING : Before installing the faceplate, make sure any masonry that has been
treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash
(muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution,
the gold or nickel face may develop a permanent tarnish when the acid evaporates over time. Contact
your dealer if uncertain your facing has been properly neutralized.
6
Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if
necessary.
To adjust the pilot flame, turn this screw. Clockwise
lowers the flame while counter-clockwise raises it.
Travis Industries
Finalizing the Installation
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
Standard
Screwdriver
4 0 4 1 0 2 8
1 0 0 - 0 1 1 5 1