Replacing the magnetic solenoid valve

Using a Phillips screwdriver, connect the electrical connector from the MCS unit to the magnetic
1.
solenoid by inserting and tightening one Phillips screw.
Adjust the water hoses connected to the rear of the bottom heat exchanger unit and hold them out of
2.
the way to reach the solenoid valve post. This process can be difficult. If you struggle excessively,
disconnect the In and Out water hoses connected to the bottom heat exchanger unit using the
counter hold wrench and the water hose fitting wrench.
Place the magnetic solenoid back on the valve post (1), and press down until the silver retainer tab
3.
locks the magnetic solenoid in place on the valve (2).
Replace the air deflector plate
4.
Replace the bottom fan unit
5.
Complete the operation checklist (on page 111).
6.
("Replacing the air deflector
("Replacing the bottom fan
plate" on page 34).
unit" on page 45).