HP 403349-003 Maintenance And Service Manual page 83

Modular cooling system
Table of Contents

Advertisement

Remove the bottom fan unit
2.
Remove the air deflector plate
3.
Adjust the water hoses connected to the rear of the bottom heat exchanger unit and hold them out of
4.
the way to reach the magnetic solenoid on the valve. This process can be difficult. If you struggle
excessively, disconnect the In and Out water hoses on the back of the bottom heat exchanger unit
using the counter hold wrench and the water hose fitting wrench.
On the magnetic solenoid valve, release the silver retainer tab (1), and remove the magnetic
5.
solenoid from the valve post (2).
Using a Phillips screwdriver, remove the Phillips screw securing the electrical connector to the
6.
magnetic solenoid.
To replace the component, see "Replacing the magnetic solenoid valve (on page 84)."
("Removing the bottom fan
("Removing the air deflector
unit" on page 44).
plate" on page 33).
Removal and replacement procedures 83

Advertisement

Table of Contents
loading