10” compound miter saw
Table of Contents

Advertisement

.
If the Saw Blade (5) touches the Table (1) or any other part of the Saw
Base (), tighten the Screw (92) to raise the Saw Blade slightly until it clears.
(See Figure O.)
SCREW (92)
FIgURE O
To Adjust The Miter Angle:
1.
WARNINg! Prior to performing this procedure, make sure the Power
Cord (102) of the Miter Saw is unplugged from its electrical outlet.
2.
The miter angle of a cut may be adjusted 0 - 45 degrees to the right or left. To do
so, depress the Angle Lock (4) located at the front of the Table (1).
(See Figure O.)
3.
While the Angle Lock (4) is depressed, move the Handle (1) to the right or left
until the desired miter angle of cut is indicated by the Gauge () located on the
Base (). Then, release pressure on the Angle Lock to lock the Miter Saw in
place. (See Figure O.)
To Adust The Bevel Of Cut:
1.
WARNINg! Prior to performing this procedure, make sure the Power
Cord (102) of the Miter Saw is unplugged from its electrical outlet.
SKU 91995
For technical questions, please call 1-800-444-3353.
TABlE (18)
KERF BOARD (11)
ANglE lOCK (4)
HANDlE (1)
gAUgE (6)
BASE (8)