Black Box 3600 User Manual page 164

Hide thumbs Also See for 3600:
Table of Contents

Advertisement

Status Registers
Disconnect Buffer Delay
The S62 register determines the delay before disconnect, to allow buff-
ers to empty, when disconnect conditions exist.
Bit
Value Command Description
7-0
0
%D
1-255
%Dn
Maximum Transmit Block Size
The S63 register sets the maximum transmit block size.
Bit
Value Command Description
7-0
63
\A
127
\A1
191
\A2
255
\A3
Auto-Reliable Fallback Character S64
The S64 register stores the selected ASCII value of the auto-reliable
fallback character.
Bit
Value Command Description
7-0
0
%A
1-127
%An
S65-66
Reserved
10-20
S62
Buffer disabled
Disconnect buffer delay value (seconds)
S63
Maximum block size = 64
Maximum block size = 128
Maximum block size = 192
Maximum block size = 256
Disable auto-reliable fallback
character
ASCII value 1-127
Modem 3600

Advertisement

Table of Contents
loading