Chapter 5 Troubleshooting
No. Class
Status
9.
The LINK/ACT
LED for the
LAN port is not
10.
turned on.
11.
12.
Device setting
through a LAN
is disabled.
13.
IP-9610
Description
Is the power to the communication
destination device turned on?
Are the LINK LEDs on this device
and the hub turned on?
Is the IP address specified from the
Web browser correct?
Are the network settings (IP
address, subnet mask, etc.) on the
control terminal PC correct?
Is a reply received in response to a
PING command issued to the IP
address of the device?
Recommended action
Verify the power supply and operation of
the communication destination device.
If the LINK LEDs are not ON, the LAN
cable is not connected. Connect the LAN
cable correctly.
Specify a correct IP address from the Web
browser on the control terminal.
Make correct settings by referring to the PC
user's guide and OS handbook. If this
device is started with the default settings
made before shipment from the factory, see
"Section 3.4, " Special Use of CANCEL
Key," for the network settings for the
control terminal PC.
If a reply is not received, turn on the power
to the device while holding down the
Cancel key to start the system with the
default IP address (10.0.0.1) set before
shipment from the factory. Confirm the IP
address. If the problem persists, check the
status on the LAN. For information on
this startup procedure, see Section 3.4,
"Special Use of CANCEL Key."