Rear Panel Ports - Patton SmartNode 4970 Series User Manual

Smartnode 4970 series multi-port t1/e1/pri ipv6-ready enterprise voip media gateway
Hide thumbs Also See for SmartNode 4970 Series:
Table of Contents

Advertisement

SmartNode 4970 User Manual
Port
ETH 0/0
PRI 0/0
PRI 0/1
PRI 0/2
PRI 0/3
Console
DC power input
Reset
SmartNode 4970 rear panel
Table 3. Rear panel ports
Auto-MDX Gigabit-Ethernet port, RJ-45 (see
WAN device (for example, a cable modem, DSL modem, or fiber modem). Note:
Only full duplex modes are supported.
RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet-
ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1
interface cable for 120 Ohm balanced connections to connect the SmartNode with
an NT or ET, e.g. a PBX or LE.
RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet-
ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1
interface cable for 120 Ohm balanced connections to connect the SmartNode with
an NT or ET, e.g. a PBX or LE.
RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet-
ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1
interface cable for 120 Ohm balanced connections to connect the SmartNode with
an NT or ET, e.g. a PBX or LE.
RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet-
ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1
interface cable for 120 Ohm balanced connections to connect the SmartNode with
an NT or ET, e.g. a PBX or LE.
Used for service and maintenance, the Console port (see
connector, connects the product to a serial terminal such as a PC or ASCII terminal
(also called a dumb terminal).
Electricity supply socket. (see
The reset button (see
figure 2
Restart the unit with the current startup configuration—Press (for less than 1 second)
and release the Reset button to restart the unit with the current startup configuration.
Restart the unit with factory default configuration—Press the Reset button for
5 seconds until the Power LED (see
the unit with factory default configuration.
Restart the unit in bootloader mode (to be used only by trained SmartNode tech-
nicians)—Starting with the unit powered off, press and hold the Reset button as
you apply power to the unit. Release the Reset button when the Power LED starts
blinking so the unit will enter bootloader mode.
Description
figure 2
figure 2
).
) has three functions:
on page 18) starts blinking to restart
figure 3
1 • General information
), connects the unit to an Ethernet
figure 2
), an RS-232 RJ-45
17