6.8.2

Contact

The event behavior can be configured for each of the 16 input contacts in turn.
Actions
Click Edit... to set up Recording, Monitor and PTZ actions that should be carried out when
this contact is active.
Any actions that have been configured are listed.
6.8.3

Motion

The event behavior for motion detection can be configured for each video channel in turn.
Actions
Click Edit... to set up Recording, Monitor and PTZ actions that should be carried out when
motion is detected.
Any actions that have been configured are listed.
6.8.4

Text

The event behavior for text can be configured for each video channel in turn.
Actions
Click Edit... to set up Recording, Monitor and PTZ actions that should be carried out when
text is detected.
Any actions that have been configured are listed.
F.01U.246.471 | v3.4 | 2011.06
Check the Enabled box if the input contact should activate an event.
Check the Alarm box if the input contact should activate an alarm.
Recording: highlight the video channels to be recorded at contact recording settings
when this input contact is active (highlight the un-numbered box to select all). A list of
the selected channels and their recording properties is shown.
Monitor: highlight the video channels to be displayed on monitors A and B when this
input contact is active (highlight the un-numbered box to select all).
PTZ: enter a pre-position number from 1-1023 for each of the PTZ cameras that should
be moved (PTZ must be enabled for corresponding camera input).
Check the Enabled box if motion detection should activate an event.
Check the Alarm box if motion detection should activate an alarm.
Recording: highlight the video channels to be recorded at motion recording settings
when motion is detected (highlight the un-numbered box to select all). A list of the
selected channels and their recording properties is shown.
Monitor: highlight the video channels to be displayed on monitors A and B when motion
is detected (highlight the un-numbered box to select all).
PTZ: enter a pre-position number from 1-1023 for each of the PTZ cameras that should
be moved (PTZ must be enabled for corresponding camera input).
Check the Enabled box if text should activate an event.
Check the Alarm box if text should activate an alarm.
Recording: highlight the video channels to be recorded at text recording settings when
text is detected (highlight the un-numbered box to select all). A list of the selected
channels and their recording properties is shown.
Monitor: highlight the video channels to be displayed on monitors A and B when text is
detected (highlight the un-numbered box to select all).
PTZ: enter a pre-position number from 1-1023 for each of the PTZ cameras that should
be moved (PTZ must be enabled for corresponding camera input).