Injectors Table - Fisher & Paykel OR36SDBGX Installation Instructions Manual

Freestanding range
Hide thumbs Also See for OR36SDBGX:
Table of Contents

Advertisement

Available languages

Available languages

b
2
BURNERS
Semi-rapid (R)
Triple ring (TC)
Inner crown
Dual (D)
Outer crowns
Oven burner
Broil burner
(*) Power calculated only with inner crown operating
(#) Power calculated with inner and outer crowns operating
Semi-rapid
burner
Fig. 2.6a
DUAL
burner
J
Injectors for
outer crowns
Fig. 2.6c
20

INJECTORS TABLE

NOMINAL POWER
BTU/hr
6000
12000
2800
for NATURAL GAS (*)
3500
for LP/PROPANE GAS (*)
16000
for NATURAL GAS (#)
15000
for LP/PROPANE GAS (#)
21000
15000
Triple ring
burner
J
Fig. 2.6b
REDUCED POWER
BTU/hr
1500
5000
1000 (*)
6500
for NATURAL GAS (#)
4500
for LP/PROPANE GAS (#)
2700
-
J
Injector for inner crown
LP/PROPANE
11" W.C.P.
Ø injector
[1/100 mm]
72
102
55
(no. 1 central)
72
(no. 2 outer)
135
115
OPERATIONS TO BE
PERFORMED WHEN
SUBSTITUTING THE
INJECTORS
J
✓ Remove the gratings and the burner
covers;
✓ Using a wrench substitute the nozzle
injectors "J" (figs. 2.6a - 2.6b - 2.6c)
with those most suitable for the kind of
gas for which it is to be used.
The burner are conceived in such a way
so as not to require the regulation of the
primary air.
NATURAL GAS
4" W.C.P.
Ø injector
[1/100 mm]
118
170
80
(no. 1 central)
130
(no. 2 outer)
247
200

Advertisement