Download Print this page

Injectors Table - Fisher & Paykel OR30SCG4R1 Manual

Gas conversion
Hide thumbs Also See for OR30SCG4R1:

Advertisement

To set the Pressure Regulator
1. Unscrew the regulator cover.
2. Unscrew the C component, reverse and screw it according to the LP/PROPANE (or NATURAL GAS)
regulation.
To Replace the Storage/Warming Drawer
1. Insert the storage/warming drawer guides into the range guides.
2. Gently close the drawer completely; the safety catches will automatically hook into place.

Injectors Table

Burners
Semirapid (SR)
Inner
crown
Dual
(D)
Full
burner
OR30 Gas Models Only
Oven burner
https://producthelp.fisherpaykel.com/us/Cook/Ranges/Gas/OR30SCG4R1/Installation_Guide_OR30SCG4R1/19_Gas_Conver...
Reduced
Nominal Power
Power
BTU/HR
BTU/HR
7600 (LP/
Propane Gas)
8000 (Natural
Gas)
1
2800
1100
2
18000
6500
14000
LP/Propane 11"
(279.4mm) W.C.P
Ø Injector [1/100 MM]
1800
1800
1
2
79 (x2)
2400
109
(101.6mm) W.C.P.
Ø Injector [1/100 MM]
78
-
3
47
4
Updated: Thu, 02 Dec 2021 09:44:40 GMT
Natural Gas 4"
-
136
3
80
4
135 (x2)
190
Powered by
3

Advertisement

loading