Contacts; Contact Inputs; Relay Outputs; Contact Input Properties - Bosch DHR-1600A-150A Installation Manual

Digital hybrid recorder
Hide thumbs Also See for DHR-1600A-150A:
Table of Contents

Advertisement

Divar XF
3.
4.
5.
6.
7.
6.5

Contacts

Use the Contacts menu to set up alarm inputs and relay outputs.
Figure 6.6 Contacts menu
6.5.1

Contact inputs

By default, all contact Inputs are Normally Open (NO). Highlight contact inputs that you wish
to function as Normally Closed (NC) contacts (highlight the un-numbered box to select all).
6.5.2

Relay outputs

By default, all relay output contacts are Normally Open (NO). Highlight the relay outputs that
you wish to function as Normally Closed (NC) contacts.
6.5.3

Contact input properties

Each of the 16 contact inputs can be assigned a name and a profile override mode.
Profile overrides
An alarm input can activate a profile override. There are three modes available:
Bosch Security Systems
Highlight the profiles to copy to (highlight the un-numbered box to select all).
Select the camera input(s) to be copied from, for the profile to be copied.
Select the camera inputs to be copied to (hightlight the un-numbered box to select all).
Check only those recording modes (Normal, Alarm or Motion) that you wish to copy.
Click Copy.
No override (default)
Follows: the profile override lasts for as long as the input is active (no override duration
can be set).
Installation manual
Advanced configuration menu | en
F.01U.135.429 | 2.5 | 2009.08
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Divar xf

Table of Contents