Fan Locations - HP ProLiant DL585 User Manual

Generation 6
Hide thumbs Also See for ProLiant DL585:
Table of Contents

Advertisement

LED3 pattern
One blink per
second
Steady glow
One blink per
second

Fan locations

Item
1
2
3
4
5
6
LED4 pattern
Interpretation
capacity expansion, stripe size migration, and RAID migration) are
temporarily unavailable until charging is complete. The recharge
process takes between 15 minutes and two hours, depending on
the initial capacity of the battery.
Steady glow
The battery pack is fully charged, and posted write data is stored
in the cache.
Off
The battery pack is fully charged, and there is no posted write data
in the cache.
One blink per
An alternating green and amber blink pattern indicates that the
second
cache microcontroller is executing from within its boot loader and
receiving new flash code from the host controller.
There is a short circuit across the battery terminals or within the
battery pack. BBWC features are disabled until the battery pack is
replaced. The life expectancy of a battery pack is typically more
than three years.
There is an open circuit across the battery terminals or within the
battery pack. BBWC features are disabled until the battery pack is
replaced. The life expectancy of a battery pack is typically more
than three years.
Description
Fan 3
Fan 4
Fan 1
Fan 2
Fan 5
Fan 6
Component identification 19